Sample Record

Owner Lab

  • CT D02 - Redding Northern Regional Laboratory

DIME Sample ID 2024-07-02-134

Project Information

Project IdentifiersProject ID: 66669
DEA: JMF-DATA
EFIS: JMF-DATA
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for storing JMF sample data
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date07/02/2024 Sample Unique Key134
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/02/2024
Sample typeVerification A brief description of the sampleCombined Untreated 1/2-inch Type G Aggregate
The quantity of what the sample constitutesJMF From where was the sample collectedManufacturer
First name of sampler or witnessed byWard Last name of sampler or witnessed byJenkins
Title of samplerNot set Telephone number of samplerNot set
Laboratory sample identificationNot set Linked DIME Sample IDNot set
The fabricator/manufacturer/facility nameHat Creek Construction & Materials — Ward Lake Plant (Litchfield, CA) Transportation Laboratory (TL) NumberNot set
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-18-0008::Ward Lake Pit (Litchfield, CA)
The fabricator's/manufacturer's product name for the sampleNot set The fabricator/manufacturer designation for the sampleNot set
The plant numberNot set A detailed description of where the material sample was collectedLaboratory-Batched from Untreated Sized Virgin Aggregate Stockpile samples
Where the material sample would have been placed if not sampledNot set Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set

JMF Information

Verification IDJMF3513-2025-38 Date Created06/26/2025
JMF Submittal IDJMF3511-22-2025-39 JMF StatusSubmittal Authorized For Use
Producer Mix ID23-1278.169-0.75RHMA-G PG 58-22 Authorized Date06/27/2025

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2024-07-02-134-1AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)Sean McWithey and Dacota Mei, CT D02 - Redding Northern Regional Laboratory01/02/202506/26/2025
Yes
06/27/2025Submitted from JMF - Ward JenkinsPublic - Test Data Visible
2024-07-02-134-2AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)Dennis Hickey, CT D02 - Redding Northern Regional Laboratory10/03/202406/26/2025
Yes
06/27/2025Submitted from JMF - Ward JenkinsPublic - Test Data Visible
2024-07-02-134-3AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)Josh Ferency, CT D02 - Redding Northern Regional Laboratory01/02/202506/26/2025
Yes
06/27/2025Submitted from JMF - Ward JenkinsPublic - Test Data Visible
2024-07-02-134-4AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)Josh Ferency, CT D02 - Redding Northern Regional Laboratory01/06/202506/26/2025
Yes
06/27/2025Submitted from JMF - Ward JenkinsPublic - Test Data Visible
2024-07-02-134-5ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)Dennis Hickey, CT D02 - Redding Northern Regional Laboratory10/04/202406/26/2025
Yes
06/27/2025Submitted from JMF - Ward JenkinsPublic - Test Data Visible
2024-07-02-134-6CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)Josh Ferency, CT D02 - Redding Northern Regional Laboratory01/02/202506/26/2025
Yes
06/27/2025Submitted from JMF - Ward JenkinsPublic - Test Data Visible
2024-07-02-134-7AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)Dennis Hickey, CT D02 - Redding Northern Regional Laboratory05/29/202506/26/2025
Yes
06/27/2025Submitted from JMF - Ward JenkinsPublic - Test Data Visible
2024-07-02-134-8AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)Dennis Hickey, CT D02 - Redding Northern Regional Laboratory05/30/202506/26/2025
Yes
06/27/2025Submitted from JMF - Ward JenkinsPublic - Test Data Visible
2024-07-02-134-9AASHTO T210-15: Standard Method of Test for Aggregate Durability Index (Durability Index)Josh Ferency, CT D02 - Redding Northern Regional Laboratory01/02/202506/26/2025
Yes
06/27/2025Submitted from JMF - Ward JenkinsPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-07-02-134-1 AASHTO T335-09r13 (Verified)
DIME Test ID: 2024-07-02-134-2 AASHTO T96-02r10 (Verified)
DIME Test ID: 2024-07-02-134-3 AASHTO T176-08 (Verified)
DIME Test ID: 2024-07-02-134-4 AASHTO T304-11 (Verified)
DIME Test ID: 2024-07-02-134-5 ASTM D4791-10 (Verified)
DIME Test ID: 2024-07-02-134-6 CTM 204-June 2010 (Verified)
DIME Test ID: 2024-07-02-134-7 AASHTO T85-13 (Verified)
DIME Test ID: 2024-07-02-134-8 AASHTO T84-14 (Verified)
DIME Test ID: 2024-07-02-134-9 AASHTO T210-15 (Verified)