Sample Record

Owner Lab

  • RMA Group - Rancho Cordova

DIME Sample ID 2025-04-30-72

Project Information

Project IdentifiersProject ID: 1000409
DEA: 051S1604
EFIS: 0524000176
DIST-CO-RTE-PM05-MON-1-60
Award DateNot set
Closeout DateNot set
Work DescriptionRocky Creek Slip Out Permanent Restoration Project
Location DescriptionNot set
QA Service Level1 (Verified on 06/26/2024)

Sample Information

Sample Taken Date04/30/2025 Sample Unique Key72
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/30/2025
Sample typeQuality Control A brief description of the sampleconcrete
The quantity of what the sample constitutes100cy From where was the sample collectedJob Site
First name of sampler or witnessed byRaul Last name of sampler or witnessed byAtilano
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGraniterock Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number571957e8SI
The truck number from where the sample was collected2432 The batch plant ticket number from where the sample was collected62
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedconcrete truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2025-04-30-72-1CTM 518-June 2010: Method of Test for Unit Weight of Fresh ConcreteRaul Atilano, RMA Group - Rancho Cordova04/30/202506/19/2025
No
2025-04-30-72-2CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement ConcreteRaul Atilano, RMA Group - Rancho Cordova04/30/202506/19/2025
No
2025-04-30-72-3ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement ConcreteRaul Atilano, RMA Group - Rancho Cordova04/30/202506/19/2025
No
2025-04-30-72-4CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure MethodRaul Atilano, RMA Group - Rancho Cordova04/30/202506/19/2025
No
2025-04-30-72-5CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersTodd Strait, RMA Group - Rancho Cordova05/28/202506/19/2025
No

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2025-04-30-72-1 CTM 518-June 2010
DIME Test ID: 2025-04-30-72-2 CTM 557-June 2020
DIME Test ID: 2025-04-30-72-3 ASTM C143-20
DIME Test ID: 2025-04-30-72-4 CTM 504-June 2010
DIME Test ID: 2025-04-30-72-5 CTM 521-June 2020