Sample Record
Owner Lab
- RMA Group - Rancho Cordova
DIME Sample ID 2025-04-30-72
Project Information
| Project Identifiers | Project ID: 1000409 DEA: 051S1604 EFIS: 0524000176 |
|---|---|
| DIST-CO-RTE-PM | 05-MON-1-60 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Rocky Creek Slip Out Permanent Restoration Project |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 06/26/2024) |
Sample Information
| Sample Taken Date | 04/30/2025 | Sample Unique Key | 72 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/30/2025 |
| Sample type | Quality Control | A brief description of the sample | concrete |
| The quantity of what the sample constitutes | 100cy | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Raul | Last name of sampler or witnessed by | Atilano |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Graniterock | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 571957e8SI |
|---|---|---|---|
| The truck number from where the sample was collected | 2432 | The batch plant ticket number from where the sample was collected | 62 |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | concrete truck | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Submitted Tests
| DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Date Added | Verified? | Release Date | Test Comments | Privacy Level | Actions |
|---|---|---|---|---|---|---|---|---|---|
| 2025-04-30-72-1 | CTM 518-June 2010: Method of Test for Unit Weight of Fresh Concrete | Raul Atilano, RMA Group - Rancho Cordova | 04/30/2025 | 06/19/2025 | No | ||||
| 2025-04-30-72-2 | CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement Concrete | Raul Atilano, RMA Group - Rancho Cordova | 04/30/2025 | 06/19/2025 | No | ||||
| 2025-04-30-72-3 | ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete | Raul Atilano, RMA Group - Rancho Cordova | 04/30/2025 | 06/19/2025 | No | ||||
| 2025-04-30-72-4 | CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure Method | Raul Atilano, RMA Group - Rancho Cordova | 04/30/2025 | 06/19/2025 | No | ||||
| 2025-04-30-72-5 | CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders | Todd Strait, RMA Group - Rancho Cordova | 05/28/2025 | 06/19/2025 | No |
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2025-04-30-72-1 CTM 518-June 2010
DIME Test ID: 2025-04-30-72-2 CTM 557-June 2020
DIME Test ID: 2025-04-30-72-3 ASTM C143-20
DIME Test ID: 2025-04-30-72-4 CTM 504-June 2010
DIME Test ID: 2025-04-30-72-5 CTM 521-June 2020