Sample Record
Owner Labs
- CT HQ - QASI Los Angeles Field Office
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2025-06-10-2
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 215365 DEA: 120Q9704 EFIS: 1218000010 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-405-0/11.4 |
| Award Date | 07/27/2023 |
| Closeout Date | Not set |
| Work Description | I-405 improvement project from I-5 to Harbor Boulevard including extend pavement life, improve safety, enhance traffic operation, and incorporate Intelligent Transportation Systems (ITS). |
| Location Description | Orange County I-405 PM 0 - 11.4 |
| QA Service Level | 1 (Verified on 07/01/2021) |
Sample Information
| Sample Taken Date | 06/10/2025 | Sample Unique Key | 2 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/09/2025 |
| Sample type | Quality Assurance | A brief description of the sample | 2" x 60" F1554 grade 55 Bolts |
| The quantity of what the sample constitutes | 2 samples from 170ea. | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Osiel | Last name of sampler or witnessed by | Ramirez |
| Title of sampler | Quality Assurance Inspector | Telephone number of sampler | (916) 767-3535 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Madden Bolts | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L123-049-25 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 3137948 , 20947320, 242790 | Nut Mfg. Lot Number(s) | BVWK |
| Washer Mfg. Lot Number(s) | 1024-417 | Bolt Specification | ASTM F1554 GR 55 |
| Bolt Length(s) | 60" | Nut Specification | ASTM A194 |
| Washer Specification | ASTM F436 | Finish | HDG/ PLAIN |
| Diameter/Size | 2" | Bolt Mfg. Lot Number | lot 1 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2025-06-10-2-1 ASTM B499-09r21 (Verified)
DIME Test ID: 2025-06-10-2-2 ASTM B499-09r21 (Verified)
DIME Test ID: 2025-06-10-2-3 ASTM B499-09r21 (Verified)
DIME Test ID: 2025-06-10-2-4 ASTM B499-09r21 (Verified)
DIME Test ID: 2025-06-10-2-5 ASTM B499-09r21 (Verified)
DIME Test ID: 2025-06-10-2-6 ASTM B499-09r21 (Verified)
DIME Test ID: 2025-06-10-2-7 ASTM B499-09r21 (Verified)
DIME Test ID: 2025-06-10-2-8 ASTM B499-09r21 (Verified)
DIME Test ID: 2025-06-10-2-9 ASTM E18-20 (Verified)
DIME Test ID: 2025-06-10-2-10 ASTM E18-20 (Verified)
DIME Test ID: 2025-06-10-2-11 ASTM E18-20 (Verified)
DIME Test ID: 2025-06-10-2-12 ASTM E18-20 (Verified)
DIME Test ID: 2025-06-10-2-13 ASTM E18-20 (Verified)
DIME Test ID: 2025-06-10-2-14 ASTM E18-20 (Verified)
DIME Test ID: 2025-06-10-2-15 ASTM E18-20 (Verified)
DIME Test ID: 2025-06-10-2-16 ASTM E18-20 (Verified)
DIME Test ID: 2025-06-10-2-17 ASTM E18-20 (Verified)
DIME Test ID: 2025-06-10-2-18 ASTM F606-21 (Verified)