Sample Record

Owner Labs

  • CT D04 - Fairfield Construction Field Office 59-545
  • CT HQ - Vallejo Field Laboratory

DIME Sample ID 2025-06-03-62

Project Information

Project IdentifiersProject ID: 215677
DEA: 044G0804
EFIS: 0412000332
COOP: 042676
DIST-CO-RTE-PM04-SOL-80-R10.4/30.2
Award Date01/18/2022
Closeout DateNot set
Work DescriptionHighway widening, overhead signs, and electronic toll system.
Location DescriptionIn Solano County in Fairfield and Vacaville from 1.0 mile west of Red Top Road Undercrossing to 0.4 mile east of Leisure Town Road Overcrossing.
QA Service Level1 (Verified on 04/11/2022)

Sample Information

Sample Taken Date06/03/2025 Sample Unique Key62
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/09/2025
Sample typeQuality Assurance A brief description of the sample4x8 concrete cylinders
The quantity of what the sample constitutes3 cylinders From where was the sample collectedJob Site
First name of sampler or witnessed byLam Last name of sampler or witnessed byNguyen
Title of sampler Telephone number of sampler5103858258
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCemex Fairfield Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameDavis Bridge: WB Approach Slabs Right Shoulder Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number1615759
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected31631090
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedback of truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2025-06-03-62-1ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concretelam nguyen, CT D04 - Fairfield Construction Field Office 59-54510/10/202510/10/2025
No
Concrete temp.: 77F tested by RMA
2025-06-03-62-2ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concretelam nguyen, CT D04 - Fairfield Construction Field Office 59-54510/10/202510/10/2025
No
Slump: 4" tested by RMA
2025-06-03-62-3ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensNikhil Moon, CT HQ - Vallejo Field Laboratory07/08/202507/08/2025
Yes
07/08/2025Mix Design: 1615759Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2025-06-03-62-1 ASTM C1064-17
DIME Test ID: 2025-06-03-62-2 ASTM C143-20
DIME Test ID: 2025-06-03-62-3 ASTM C39-17a (Verified)