Sample Record
DIME Sample ID 2025-05-19-2
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 214951 DEA: 120K0234 EFIS: 1214000100 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-5-17.1/18.9 |
| Award Date | 09/23/2020 |
| Closeout Date | 02/09/2026 |
| Work Description | South County Improvement Project (Phase 3 - El Toro/Alicia) WIDEN FREEWAY AND BRIDGES, RECONSTRUCT BRIDGE AND WALLS. |
| Location Description | ORANGE COUNTY IN MISSION VIEJO, LAGUNA HILLS, LAGUNA WOODS AND LAKE FOREST FROM 0.4 MILE SOUTH OF ALICIA PARKWAY OVERCROSSING TO 0.2 MILE NORTH OF EL TORO ROAD UNDERCROSSING |
| QA Service Level | 1 (Verified on 10/01/2020) |
Owner Labs
- CT HQ - QASI Los Angeles Field Office
- CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Information
| Sample Taken Date | 05/19/2025 | Sample Unique Key | 2 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 05/22/2025 | Sample type | Quality Assurance |
| A brief description of the sample | 1" F1554 grade 36 All threaded rod | The quantity of what the sample constitutes | 1 Sample from 8 total |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Jacob |
| Last name of sampler or witnessed by | Garcia | Title of sampler | LA METS QA Inspector |
| Telephone number of sampler | (760) 686-6753 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | CraneVeyor Corp | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | L169-016-25 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | Bolt-1000128350 Nut-5805574803 Washer-42329370 | Nut Mfg. Lot Number(s) | 38534-5805574803 |
| Washer Mfg. Lot Number(s) | 176720 | Bolt Specification | ASTM F1554 Gr. 36 |
| Bolt Length(s) | Nut Specification | ASTM A563 GR DH | |
| Washer Specification | ASTM F436 | Finish | ASTM A153/F2329- Hot Dip Galvanized |
| Diameter/Size | 1" | Bolt Mfg. Lot Number | 2502111-19A |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2025-05-19-2-1 ASME B1.2-83r17 (Verified)
DIME Test ID: 2025-05-19-2-2 ASME B1.2-83r17 (Verified)
DIME Test ID: 2025-05-19-2-3 ASTM B499-09r21 (Verified)
DIME Test ID: 2025-05-19-2-4 ASTM B499-09r21 (Verified)
DIME Test ID: 2025-05-19-2-5 ASTM B499-09r21 (Verified)
DIME Test ID: 2025-05-19-2-6 ASTM E18-20 (Verified)
DIME Test ID: 2025-05-19-2-7 ASTM F606-21 (Verified)