Sample Record

DIME Sample ID 2025-04-21-1

Project Information

Project IdentifiersProject ID: 994326
DEA: 051C3604
EFIS: 0512000134
DIST-CO-RTE-PM05-SB-217-0.9/1.4
Award Date01/31/2023
Closeout DateNot set
Work DescriptionREPLACE BRIDGE.
Location DescriptionSANTA BARBARA COUNTY NEAR GOLETA FROM 0.2 MILE EAST OF GOLETA SLOUGH BRIDGE TO 0.4 MILE EAST OF SAN JOSE CREEK BRIDGE
QA Service Level1 (Verified on 10/17/2022)

Owner Labs

  • CT HQ - QASI Los Angeles Field Office
  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date04/21/2025 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing04/28/2025 Sample typeQuality Assurance
A brief description of the sampleFlash Welded Rebar Hoops The quantity of what the sample constitutes8 of 1934
From where was the sample collectedFabricator First name of sampler or witnessed byAlex
Last name of sampler or witnessed byTemme Title of samplerQA
Telephone number of sampler415-238-5839 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameRKR
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL180-003-25
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)173522
Hoop Manufacturer Lot Number(s)39 and 45 Material Standard CodeASTM A706
Material Grade60 Rebar Size#6
Diameter of Hoop2'-6" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCascade
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2025-04-21-1-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory05/19/202505/19/2025
Yes
05/19/2025Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
COVER SHEET TM5 Welded Hoops rev 2025-04-21-1 (1)pdf05/05/2025   Info
20235911.005A_20250421_25-SAC-00312_Metal_DIME ID# 2025-04-21-1pdf05/05/2025   Info
20235911.005A_20250421_25-SAC-00313_Metal_DIME ID# 2025-04-21-1pdf05/05/2025   Info

Test File Attachments


DIME Test ID: 2025-04-21-1-1 CTM 670-December 2013 (Verified)