Sample Record

DIME Sample ID 2017-06-19-9

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211235
DEA: 054482U4
EFIS: 0500000543
DIST-CO-RTE-PM05-SB-101-2.2/3.3
Award Date06/20/2016
Closeout Date08/23/2021
Work DescriptionBUILD AND RECONSTRUCT BRIDGES, CONSTRUCT RAMPS AND FRONTAGE ROAD.
Location DescriptionSANTA BARBARA COUNTY IN CARPINTERIA FROM 0.2 MILE SOUTH OF CARPINTERIA CREEK BRIDGE TO FRANKLIN CREEK BRIDGE
QA Service Level1 (Verified on 07/27/2016)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date06/19/2017 Sample Unique Key9
Date that the sample was received by the laboratory/organization performing the testing06/20/2017 Sample typeQuality Assurance
A brief description of the sampleFlash Welded Rebar Hoops The quantity of what the sample constitutes8
From where was the sample collectedFabricator First name of sampler or witnessed byEd
Last name of sampler or witnessed byFleming Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameHarris Salinas
Transportation Laboratory (TL) NumberC703742 Inspector Lot Number from the Transportation Laboratory (TL) FormB1021817
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)SE15101992
Hoop Manufacturer Lot Number(s)H09, H10 Material Standard CodeASTM A706
Material Grade60 Rebar Size8
Diameter of Hoop3'-1.5" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerHarris Salinas
Welding CompanyHarris Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2017-06-19-9-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/21/201706/21/2017
Yes
06/28/2017Bar Broke; OK NeckingPublic - Test Data Visible
2017-06-19-9-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/21/201706/21/2017
Yes
06/28/2017Bar Broke; OK NeckingPublic - Test Data Visible
2017-06-19-9-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/21/201706/21/2017
Yes
06/28/2017Bar Broke; OK NeckingPublic - Test Data Visible
2017-06-19-9-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/21/201706/21/2017
Yes
06/28/2017Bar Broke; OK NeckingPublic - Test Data Visible
2017-06-19-9-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/21/201706/21/2017
Yes
06/28/2017Bar Broke; OK NeckingPublic - Test Data Visible
2017-06-19-9-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/21/201706/21/2017
Yes
06/28/2017Bar Broke; OK NeckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-06-19-9-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-06-19-9-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-06-19-9-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-06-19-9-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-06-19-9-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-06-19-9-6 CTM 670-December 2013 (Verified)