Sample Record
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2017-06-14-17
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 8196 DEA: 59912684 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | |
| Location Description | |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 06/14/2017 | Sample Unique Key | 17 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/16/2017 |
| Sample type | Quality Assurance | A brief description of the sample | A449 HDG bolt with nut, washer. A325 Bolt |
| The quantity of what the sample constitutes | 12 | From where was the sample collected | Distributor |
| First name of sampler or witnessed by | Amy | Last name of sampler or witnessed by | Bihary |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Hodell-Natco | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | Nut Mfg. Lot Number(s) | 383381C | |
| Washer Mfg. Lot Number(s) | 1216-412 | Bolt Specification | A449, A325 |
| Bolt Length(s) | 6", 1.25" | Nut Specification | A563 |
| Washer Specification | F436 | Finish | HDG |
| Diameter/Size | 0.625", 1.25" | Bolt Mfg. Lot Number | 44105, 780273 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2017-06-14-17-1 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-06-14-17-2 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-06-14-17-3 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-06-14-17-4 ASTM B499-14 (Verified)
DIME Test ID: 2017-06-14-17-5 ASTM B499-14 (Verified)
DIME Test ID: 2017-06-14-17-6 ASTM B499-14 (Verified)
DIME Test ID: 2017-06-14-17-7 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-06-14-17-8 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-06-14-17-9 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-06-14-17-10 ASTM B499-14 (Verified)
DIME Test ID: 2017-06-14-17-11 ASTM B499-14 (Verified)
DIME Test ID: 2017-06-14-17-12 ASTM B499-14 (Verified)
DIME Test ID: 2017-06-14-17-13 ASTM B499-14 (Verified)
DIME Test ID: 2017-06-14-17-14 ASTM B499-14 (Verified)
DIME Test ID: 2017-06-14-17-15 ASTM B499-14 (Verified)
DIME Test ID: 2017-06-14-17-16 ASTM B499-14 (Verified)
DIME Test ID: 2017-06-14-17-17 ASTM B499-14 (Verified)
DIME Test ID: 2017-06-14-17-18 ASTM B499-14 (Verified)
DIME Test ID: 2017-06-14-17-19 ASTM E18-15 (Verified)
DIME Test ID: 2017-06-14-17-20 ASTM E18-15 (Verified)
DIME Test ID: 2017-06-14-17-21 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-06-14-17-22 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-06-14-17-23 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-06-14-17-24 ASTM B499-14 (Verified)
DIME Test ID: 2017-06-14-17-25 ASTM B499-14 (Verified)
DIME Test ID: 2017-06-14-17-26 ASTM B499-14 (Verified)
DIME Test ID: 2017-06-14-17-27 ASTM E18-15 (Verified)
DIME Test ID: 2017-06-14-17-28 ASTM E18-15 (Verified)
DIME Test ID: 2017-06-14-17-29 ASTM F606-14a (Verified)
DIME Test ID: 2017-06-14-17-30 ASTM F606-14 (Verified)