Sample Record
DIME Sample ID 2025-04-11-3
Project Information
| Project Identifiers | Project ID: 1000580 DEA: 071XW104 EFIS: 0723000028 |
|---|---|
| DIST-CO-RTE-PM | 07--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | VENTURA COUNTY IN CITY OF FILLMORE VEN-126REPLACE/CONSTRUCT THE FILLMORE MAINTENANCESTATION DAMAGED BY HIGH WINDS DIR\\'S EMERGENCY |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 09/09/2024) |
Owner Labs
- CT HQ - QASI Los Angeles Field Office
- CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Information
| Sample Taken Date | 04/11/2025 | Sample Unique Key | 3 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 04/17/2025 | Sample type | Quality Assurance |
| A brief description of the sample | F1554 Grade 55 HDG Anchor Bolts | The quantity of what the sample constitutes | 2 of 48 |
| From where was the sample collected | Distributor | First name of sampler or witnessed by | Lorenzo |
| Last name of sampler or witnessed by | Garcia | Title of sampler | QA |
| Telephone number of sampler | 7029172503 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Blue Circle Corp | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | L115-032-25 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
|---|---|---|---|
| Heat Number(s) | 1201061488 | Nut Mfg. Lot Number(s) | N/A |
| Washer Mfg. Lot Number(s) | N/A | Bolt Specification | F1554 |
| Bolt Length(s) | 18" - 38" | Nut Specification | N/A |
| Washer Specification | N/A | Finish | ASTM F2329 |
| Diameter/Size | 3/4 | Bolt Mfg. Lot Number | 18 inch lot 99285-1 ; 36 inch lot 99285-2 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2025-04-11-3-1 ASME B1.2-83r17 (Verified)
DIME Test ID: 2025-04-11-3-2 ASME B1.2-83r17 (Verified)
DIME Test ID: 2025-04-11-3-3 ASTM B499-09r21 (Verified)
DIME Test ID: 2025-04-11-3-4 ASTM B499-09r21 (Verified)
DIME Test ID: 2025-04-11-3-5 ASTM F606-21 (Verified)
DIME Test ID: 2025-04-11-3-6 ASTM F606-21 (Verified)