Sample Record

DIME Sample ID 2025-03-22-9

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 994582
DEA: 073203U4
EFIS: 0722000071
DIST-CO-RTE-PM07-LA-91,605-R16.6/R16.8,R0.0/R10.4
Award Date06/20/2023
Closeout DateNot set
Work DescriptionPLACE CONCRETE PAVEMENT AND HIGH FRICTION SURFACE TREATMENT.
Location DescriptionLOS ANGELES COUNTY ON ROUTE 605 FROM 0.2 MILE NORTH OF KATELLA AVENUE UNDECROSSING TO 0.1 MILE NORTH OF TELEGRAPH ROAD UNDERCROSSING AND ON ROUTE 91 FROM 0.4 MILE WEST OF ROUTE 605 UNDERCROSSING TO 0.2 MILE WEST OF ROUTE 605 UNDERCROSSING
QA Service Level1 (Verified on 07/12/2023)

Owner Lab

  • CT D07 - Plant Services, Unit 1841

Sample Information

Sample Taken Date03/22/2025 Sample Unique Key9
Date that the sample was received by the laboratory/organization performing the testing03/24/2025 Sample typeQuality Assurance
A brief description of the sample3/4 Asphalt Concrete Aggregate The quantity of what the sample constitutes750 Tons
From where was the sample collectedManufacturer First name of sampler or witnessed byHonesto
Last name of sampler or witnessed byCastillo Title of samplerMREAS
Telephone number of sampler2134537563 Laboratory sample identification009
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan Materials-Irwindale
Transportation Laboratory (TL) NumberC 003549 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0035
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedCold Feed
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2025-03-22-9-1AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)Arnold Truong, CT D07 - Plant Services, Unit 184103/26/202504/03/2025
Yes
04/11/2025This gradation test result is a combination of 75%-3/4 asphalt concrete virgin aggregate and 25% of RAPPublic - Test Data Visible
2025-03-22-9-2AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)Arnold Truong, CT D07 - Plant Services, Unit 184103/26/202504/03/2025
Yes
04/11/2025Public - Test Data Visible
2025-03-22-9-3CTM 226-July 2010: Method of Test for Determination of Moisture Content of Soils and Aggregates by Oven DryingArnold Truong, CT D07 - Plant Services, Unit 184103/26/202504/03/2025
Yes
04/11/2025Public - Test Data Visible
2025-03-22-9-4AASHTO T11-5: Standard Method of Test for Materials Finer Than 75-μm (No. 200) Sieve in Mineral Aggregates by WashingArnold Truong, CT D07 - Plant Services, Unit 184103/26/202504/03/2025
Yes
04/11/2025Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2025-03-22-9-1 AASHTO T27-14 (Verified)
DIME Test ID: 2025-03-22-9-2 AASHTO T176-08 (Verified)
DIME Test ID: 2025-03-22-9-3 CTM 226-July 2010 (Verified)
DIME Test ID: 2025-03-22-9-4 AASHTO T11-5 (Verified)