Sample Record

DIME Sample ID 2025-04-02-2

Project Information

Project IdentifiersProject ID: 994875
DEA: 101F1804
EFIS: 1016000077
DIST-CO-RTE-PM10-SJ-4-R16.0/R19.4
Award Date09/20/2023
Closeout DateNot set
Work DescriptionBRIDGE WORK, CONCRETE BARRIER, AND INSTALL RAMP METER SYSTEM.
Location DescriptionSAN JOAQUIN COUNTY IN STOCKTON AT VARIOUS LOCATIONS FROM 0.3 MILE EAST OF ROUTE 4/5 SEPARATION TO 0.4 MILE WEST OF ROUTE 4/99 SEPARATION
QA Service Level1 (Verified on 06/14/2023)

Owner Labs

  • CT HQ - QASI Los Angeles Field Office
  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date04/02/2025 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing04/09/2025 Sample typeQuality Assurance
A brief description of the sample#8 Grade 75 All- Thread Bar The quantity of what the sample constitutes107
From where was the sample collectedManufacturer First name of sampler or witnessed byAdrian
Last name of sampler or witnessed bySanchez Title of sampler
Telephone number of sampler2137133499 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameWilliams Form Engineering-SD
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL159-036-25
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingAuthorization Testing
Threaded Bar SpecificationASTM A615 Threaded Bar Grade75
Threaded Bar Type Rebar Size#8
Nut Specification for Threaded BarASTM A29 System ManufacturerWilliams Form Engineering San Diego
Epoxy Coating ColorNA Threaded Bar Application
Coating StandardsUncoated Bar Heat Number(s)1000227588
Nut Heat Number(s)1000224533 Bar Lot Number
Nut Lot Number Coupler Heat Number(s)
Coupler Grade

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2025-04-02-2-1ASTM A615-20: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory05/06/202505/06/2025
Yes
05/06/2025Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2025-04-02-2-1 ASTM A615-20 (Verified)