Sample Record

DIME Sample ID 2025-03-30-2

Project Information

Project IdentifiersProject ID: 994358
DEA: 033J3304
EFIS: 0322000251
DIST-CO-RTE-PM03-SAC-12-0/0.5
Award DateNot set
Closeout DateNot set
Work DescriptionMMBN Project. Replace backup drive system, replace lift span deck, install hydraulic barrier system and new generator, replace electrical control system, install new traffic gates and elevators, traffic control,
Location DescriptionNot set
QA Service Level1 (Verified on 10/25/2022)

Owner Labs

  • CT HQ - QASI Sacramento Field Office
  • CT HQ - Vallejo Field Laboratory

Sample Information

Sample Taken Date03/30/2025 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing03/30/2025 Sample typeQuality Assurance
A brief description of the sample15 - 4x8 and 9 - 6x12 concrete cylinders The quantity of what the sample constitutes19 CY
From where was the sample collectedJob Site First name of sampler or witnessed bySteve
Last name of sampler or witnessed byHaynes Title of samplerQuality Assurance Inspector
Telephone number of sampler5105931179 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility namePrecision Concrete Materials
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure nameRio Vista Bridge
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number90479AFP LWA-LWF-A2
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected17840
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedconcrete sample from wheelbarrow Where the material sample would have been placed if not sampledbridge deck pour 1B
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2025-03-30-2-1ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensNikhil Moon, CT HQ - Vallejo Field Laboratory04/07/202504/07/2025
Yes
04/07/2025Public - Test Data Visible
2025-03-30-2-2ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensYannick Aranas, CT HQ - Vallejo Field Laboratory04/13/202504/13/2025
Yes
04/13/2025Public - Test Data Visible
2025-03-30-2-3ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensYannick Aranas, CT HQ - Vallejo Field Laboratory04/21/202504/21/2025
Yes
04/21/2025Public - Test Data Visible
2025-03-30-2-4ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensYannick Aranas, CT HQ - Vallejo Field Laboratory04/27/202504/27/2025
Yes
04/27/2025Public - Test Data Visible
2025-03-30-2-5ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensYannick Aranas, CT HQ - Vallejo Field Laboratory03/30/202504/02/2025
Yes
04/02/2025Opening Age Breaks Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
2025-03-30-2 - 20235911.007A_20250330_25-HAY-00359_Concrete_Masonrypdf04/11/2025   Info
2025-03-30-2-20235911.007A_20250330_25-HAY-00491_Concrete_Masonry_prelimpdf05/02/2025   Info
20235911.007A_2025-03-30-2_25-HAY-00491_Concrete_Masonrypdf07/07/2025   Info

Test File Attachments


DIME Test ID: 2025-03-30-2-1 ASTM C39-17a (Verified)
DIME Test ID: 2025-03-30-2-2 ASTM C39-17a (Verified)
DIME Test ID: 2025-03-30-2-3 ASTM C39-17a (Verified)
DIME Test ID: 2025-03-30-2-4 ASTM C39-17a (Verified)