Sample Record

DIME Sample ID 2025-03-20-17

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 995201
DEA: 061G3104
EFIS: 0623000239
DIST-CO-RTE-PM06-KER-178-20.6/21.6
Award Date06/02/2023
Closeout Date12/02/2025
Work DescriptionRoadway / retaining wall / slope repairs
Location DescriptionNot set
QA Service Level1 (Verified on 10/06/2023)

Owner Lab

  • CT D06 - Bakersfield Field Laboratory

Sample Information

Sample Taken Date03/20/2025 Sample Unique Key17
Date that the sample was received by the laboratory/organization performing the testing03/21/2025 Sample typeAcceptance
A brief description of the samplePCC cylinders retaining wall The quantity of what the sample constitutes0 to 300 cy
From where was the sample collectedJob Site First name of sampler or witnessed byBernard
Last name of sampler or witnessed byGUINTO Title of samplerInspector
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility name711 materials
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number750216A6
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedNA
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedBACK OF THE TRUCK Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2025-03-20-17-1CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersNeale, CT D06 - Bakersfield Field Laboratory03/25/202503/25/2025
Yes
03/25/2025Public - Test Data Visible
2025-03-20-17-2CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersNeale, CT D06 - Bakersfield Field Laboratory03/27/202503/27/2025
Yes
03/27/2025Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2025-03-20-17-1 CTM 521-June 2020 (Verified)
File NameExtensionDate UploadedTest IDActions
06-1G3104_370XX_250320_1_5Dpdf03/25/20252025-03-20-17-1   Info

DIME Test ID: 2025-03-20-17-2 CTM 521-June 2020 (Verified)
File NameExtensionDate UploadedTest IDActions
06-1G3104_370XX_250320_1_7Dpdf03/27/20252025-03-20-17-2   Info