Sample Record

DIME Sample ID 2017-06-05-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 7428
DEA: 07215944
EFIS: 0700001834
DIST-CO-RTE-PM07-LA-5-4.0/5.9
Award Date08/23/2012
Closeout Date07/02/2021
Work DescriptionRECONSTRUCT AND WIDEN FREEWAY AND UNDERCROSSING STRUCTURES.
Location DescriptionLOS ANGELES COUNTY IN NORWALK FROM 0.4 MILE SOUTH OF SAN ANTONIO DRIVE UNDERCROSSING TO 0.7 MILE NORTH OF PIONEER BOULEVARD UNDERCROSSING
QA Service Level1 (Verified on 11/07/2012)

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

Sample Information

Sample Taken Date06/05/2017 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing06/07/2017 Sample typeQuality Assurance
A brief description of the sample Resistance Butt Welded Hoops The quantity of what the sample constitutes1 lot
From where was the sample collectedFabricator First name of sampler or witnessed byRussell
Last name of sampler or witnessed byLynch Title of samplerQAI
Telephone number of sampler(213)538-8219 Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameRKR Steel Welding
Transportation Laboratory (TL) NumberC657757 Inspector Lot Number from the Transportation Laboratory (TL) FormL96-089-17
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)65026779
Hoop Manufacturer Lot Number(s)9 Material Standard CodeASTM A706
Material Grade60 Rebar Size8
Diameter of Hoop6'-6" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerGerdau
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2017-06-05-1-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/08/201706/08/2017
Yes
06/15/2017Bar Broke; OK NeckingPublic - Test Data Visible
2017-06-05-1-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/08/201706/08/2017
Yes
06/15/2017Bar Broke; OK NeckingPublic - Test Data Visible
2017-06-05-1-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/08/201706/08/2017
Yes
06/15/2017Bar Broke; OK NeckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-06-05-1-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-06-05-1-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-06-05-1-3 CTM 670-December 2013 (Verified)