Sample Record

Owner Labs

  • CT SC - 3674 - Livermore
  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2025-02-20-10

Project Information

Project IdentifiersProject ID: 209820
DEA: 04297634
EFIS: 0415000040
COOP: 042548
DIST-CO-RTE-PM04-ALA-84,680-17.9/21
Award Date02/19/2021
Closeout DateNot set
Work DescriptionROUTE 84 WIDENING (4-LANE EXPRESSWAY) FROM I-680 TO PIGEON PASS, INCLUDING INTERSECTION, DRAINAGE IMPROVEMENTS AND UTILITY RELOCATION.
Location DescriptionALAMEDA COUNTY IN AND NEAR SUNOL, PLEASANTON, AND LIVERMORE ON ROUTE 84 FROM 0.1 MILE EAST OF ROUTE 680 TO 0.1 MILE SOUTH OF RUBY HILL DRIVE AND ON ROUTE 680 FROM 1.2 MILES SOUTH TO 1.8 MILES NORTH OF ROUTE 84
QA Service Level1 (Verified on 11/04/2019)

Sample Information

Sample Taken Date02/20/2025 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing02/24/2025
Sample typeQuality Assurance A brief description of the sampleHRC 500/510 Couplers
The quantity of what the sample constitutes150 From where was the sample collectedJob Site
First name of sampler or witnessed byIbrahim Last name of sampler or witnessed byMarji
Title of samplerAssistant Structure Representative Telephone number of sampler5105094817
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHRC Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier33-0765G
Structure nameVallecitos Creek Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCamblin
Coupler ManufacturerHRC Intermediate Assembler or Fabricator
Rebar Size#11 Coupler Model500/510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)73130586, 73135166 Rebar Heat Number(s)9003993
Rebar Size 2 Coupler Unique IDTP-17-03

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2025-02-20-10-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory03/03/202503/03/2025
Yes
03/03/2025Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
COVER SHEET TM5 Couplers rev 2025-02-20-10pdf02/28/2025   Info
20235911.004A_20250220_25-SAC-00145_Metal_DIME ID # 2025-02-20-10pdf02/28/2025   Info

Test File Attachments


DIME Test ID: 2025-02-20-10-1 CTM 670-December 2013 (Verified)