Sample Record

DIME Sample ID 2017-05-23-4

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 208714
DEA: 08043514
EFIS: 0800000010
DIST-CO-RTE-PM08-SBD-58-R22.2/R31.1
Award Date12/30/2014
Closeout Date08/29/2018
Work DescriptionREALIGN AND WIDEN 2 TO 4 LANES EXPRESSWAY
Location DescriptionHINKLEY ROAD FROM 2.4 MILES WEST OF HIDDEN RIVER ROAD TO? 0.7 MILE EAST OF LENWOOD ROAD.
QA Service Level1 (Verified on 03/22/2013)

Owner Lab

  • CT D08 - Fontana Southern Regional Laboratory

Sample Information

Sample Taken Date05/23/2017 Sample Unique Key4
Date that the sample was received by the laboratory/organization performing the testing05/25/2017 Sample typeQuality Assurance
A brief description of the sample6X12 The quantity of what the sample constitutes10
From where was the sample collectedJob Site First name of sampler or witnessed byROBERT
Last name of sampler or witnessed byBERSBACH Title of samplerTECH
Telephone number of samplerUnknown Laboratory sample identification915-523
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameROBERTSONS
Transportation Laboratory (TL) Number20170523 Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierSR58 EXPRESS WAY AT HINKLEY Structure nameRW 1633 STEM WALL POUR 5
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberSC678B38
The truck number from where the sample was collected1728 The batch plant ticket number from where the sample was collected225702
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedRW 1633 STEM WALL POUR 5 Where the material sample would have been placed if not sampledRW 1633 STEM WALL POUR 5
From Lot No.Unknown Bag Lot No.Unknown

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2017-05-23-4-1ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory05/25/2017
Yes
05/25/2017Public - Test Data Visible
2017-05-23-4-2ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory05/26/2017
Yes
05/26/2017Public - Test Data Visible
2017-05-23-4-3ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory05/30/2017
Yes
05/30/2017Public - Test Data Visible
2017-05-23-4-4ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory06/13/2017
Yes
06/13/2017Public - Test Data Visible
2017-05-23-4-5ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensJose Guzman, CT D08 - Fontana Southern Regional Laboratory06/20/2017
Yes
06/20/2017Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-05-23-4-1 ASTM C39-17a (Verified)
DIME Test ID: 2017-05-23-4-2 ASTM C39-17a (Verified)
DIME Test ID: 2017-05-23-4-3 ASTM C39-17a (Verified)
DIME Test ID: 2017-05-23-4-4 ASTM C39-17a (Verified)
DIME Test ID: 2017-05-23-4-5 ASTM C39-17a (Verified)