Sample Record

DIME Sample ID 2017-05-11-3

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 9999
DEA: 00000000
EFIS: 0000000000
COOP: 99999333399
MINOR: 333333
Permit Numbers: 555555 0400NRT0000
DIST-CO-RTE-PM03-SAC,OMG-888,99,80-0.6-0.6
Award DateNot set
Closeout DateNot set
Work DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
QA Service Level1 (Verified on 04/05/2013)

Owner Lab

  • Oldcastle Precast, Incorporated - Pleasanton

Sample Information

Sample Taken Date05/11/2017 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing05/11/2017 Sample typeQuality Control
A brief description of the sampleconcrete The quantity of what the sample constitutes100 cy
From where was the sample collectedManufacturer First name of sampler or witnessed byAvery
Last name of sampler or witnessed byFlores Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameOldcastle Precast
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierUnknown Structure nameUnknown
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number123456
The truck number from where the sample was collectedUnknown The batch plant ticket number from where the sample was collected12345677
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedwheelbarrow Where the material sample would have been placed if not sampledUnknown
From Lot No.Unknown Bag Lot No.Unknown

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2017-05-11-3-1ASTM C143-10a: Standard Test Method for Slump of Hydraulic-Cement ConcreteAvery Flores, Oldcastle Precast, Incorporated - Pleasanton05/11/2017
Yes
05/07/2021Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-05-11-3-1 ASTM C143-10a (Verified)