Sample Record

DIME Sample ID 2017-05-05-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211854
DEA: 043G0804
EFIS: 0400021272
DIST-CO-RTE-PM04-SON-1-30.5
Award Date01/20/2017
Closeout Date02/27/2019
Work DescriptionCONSTRUCT ROADWAY AND SOIL NAIL WALLS
Location DescriptionSONOMA COUNTY NEAR FORT ROSS AT 2.6 MILES SOUTH OF FORT ROSS ROAD
QA Service Level1 (Verified on 03/13/2017)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date05/05/2017 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing05/09/2017 Sample typeQuality Assurance
A brief description of the sampleEpoxy coated coupler, Grade 75 The quantity of what the sample constitutes2
From where was the sample collectedManufacturer First name of sampler or witnessed byKen
Last name of sampler or witnessed byVarela Title of samplerAssociate Steel Inspector
Telephone number of sampler(213) 620-2341 Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameWilliams Form
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormL08-039-17
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A615
Material Grade60 Rebar Manufacturerunknown
Coupler ManufacturerWilliams Form Intermediate Assembler or FabricatorEaton Steel Bar Co
Rebar SizeNo. 8 Coupler Modelunknown
Coating StandardsASTM A934 Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)unknown Rebar Heat Number(s)unknown
Rebar Size 2 Not set Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2017-05-05-1-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Necking)Glen Weldon, CT HQ - Sacramento Structural Materials Testing Laboratory05/10/2017
Yes
05/18/2017Public - Test Data Visible
2017-05-05-1-2ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)Glen Weldon, CT HQ - Sacramento Structural Materials Testing Laboratory05/10/2017
Yes
05/18/2017Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-05-05-1-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-05-05-1-2 ASTM A775-07b-re14 (Verified)