Sample Record

DIME Sample ID 2024-12-05-63

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 995193
DEA: 07356604
EFIS: 0719000026
DIST-CO-RTE-PM07-LA-605-R10.2/20.2
Award Date04/04/2024
Closeout DateNot set
Work DescriptionLANE & SLAB REPLACEMENT, COLD PLANE & HMA OVERLAY.
Location DescriptionLOS ANGELES COUNTY IN SANTA FE SPRINGS, PICO RIVERA, WHITTIER, CITY OF INDUSTRY AND EL MONTE FROM TELEGRAPH ROAD UNDERCROSSING TO ROUTE 605/10 SEPARATION
QA Service Level1 (Verified on 10/03/2023)

Owner Lab

  • Alta Vista Solutions - Whittier

Sample Information

Sample Taken Date12/05/2024 Sample Unique Key63
Date that the sample was received by the laboratory/organization performing the testing12/05/2024 Sample typeQuality Assurance
A brief description of the sample6 x 12 LCB Cylinders The quantity of what the sample constitutes10 CY
From where was the sample collectedJob Site First name of sampler or witnessed byManuel
Last name of sampler or witnessed byUy Title of samplerMaterials Tester
Telephone number of sampler9495016042 Laboratory sample identification24-3757-3758-3759
Linked DIME Sample ID The fabricator/manufacturer/facility nameN/A
Transportation Laboratory (TL) NumberNA Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberVCTS675
The truck number from where the sample was collectedLoad 1 Truck 12057 The batch plant ticket number from where the sample was collectedNA
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedJobsite Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2024-12-05-63-1CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersSamir El-Chammas, Alta Vista Solutions - Whittier12/12/202412/20/2024
Yes
12/20/2024Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-12-05-63-1 CTM 521-June 2020 (Verified)