Sample Record

Owner Lab

  • CT D11 - District 11 Materials Laboratory

DIME Sample ID 2024-11-05-74

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 993318
DEA: 11423704
EFIS: 1116000059
DIST-CO-RTE-PM11-SD-8-R31.8/R41.7
Award Date04/01/2022
Closeout Date04/08/2025
Work DescriptionPLACE CRCP, HMA, MGS, AND WATER POLLUTION CONTROL SYSTEM.
Location DescriptionSAN DIEGO COUNTY NEAR ALPINE FROM VIEJAS CREEK BRIDGE TO PINE VALLEY CREEK BRIDGE
QA Service Level1 (Verified on 10/27/2021)

Sample Information

Sample Taken Date11/05/2024 Sample Unique Key74
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/09/2024
Sample typeQuality Assurance A brief description of the samplePlant Sample
The quantity of what the sample constitutes3 bags From where was the sample collectedSource
First name of sampler or witnessed byDerrick Last name of sampler or witnessed byMcCovy
Title of samplerTET Telephone number of sampler6193722435
Laboratory sample identification65118-S Linked DIME Sample ID
The fabricator/manufacturer/facility nameMartin Marietta Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Not Provided
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPlant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number6038801

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2024-11-05-74-1CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesMohammad Abbassi, CT D11 - District 11 Materials Laboratory12/19/202412/20/2024
Yes
12/23/2024Public - Test Data Visible
2024-11-05-74-2CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesMohammad Abbassi, CT D11 - District 11 Materials Laboratory12/20/202412/20/2024
Yes
12/23/2024Public - Test Data Visible
2024-11-05-74-3CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesMohammad Abbassi, CT D11 - District 11 Materials Laboratory12/20/202412/20/2024
Yes
12/23/2024Public - Test Data Visible
2024-11-05-74-4CTM 217-June 2011: Method of Test for Sand EquivalentMohammad Abbassi, CT D11 - District 11 Materials Laboratory12/19/202412/20/2024
Yes
12/23/2024Public - Test Data Visible
2024-11-05-74-5CTM 229-June 2011: Method of Test for Durability IndexMohammad Abbassi, CT D11 - District 11 Materials Laboratory12/20/202412/20/2024
Yes
12/23/20241"Public - Test Data Visible
2024-11-05-74-6CTM 229-June 2011: Method of Test for Durability IndexMohammad Abbassi, CT D11 - District 11 Materials Laboratory01/08/202501/08/2025
Yes
01/23/20253/8"Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-11-05-74-1 CTM 202-November 2011 (Verified)
DIME Test ID: 2024-11-05-74-2 CTM 202-November 2011 (Verified)
DIME Test ID: 2024-11-05-74-3 CTM 202-November 2011 (Verified)
DIME Test ID: 2024-11-05-74-4 CTM 217-June 2011 (Verified)
DIME Test ID: 2024-11-05-74-5 CTM 229-June 2011 (Verified)
DIME Test ID: 2024-11-05-74-6 CTM 229-June 2011 (Verified)