Sample Record
DIME Sample ID 2024-12-11-2
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 995495 DEA: 101C2704 EFIS: 1014000097 |
|---|---|
| DIST-CO-RTE-PM | 10-STA-5-27.1 |
| Award Date | 03/28/2024 |
| Closeout Date | Not set |
| Work Description | REPLACE SAFETY ROADSIDE REST AREA. |
| Location Description | STATE HIGHWAY IN STANISLAUS COUNTY ABOUT 1.0 MILE SOUTH OF SAN JOAQUIN COUNTY LINE AT THE WESTLEY SAFETY ROADSIDE REST AREA |
| QA Service Level | 1 (Verified on 11/20/2023) |
Owner Lab
- CT HQ - QASI Sacramento Field Office
Sample Information
| Sample Taken Date | 12/11/2024 | Sample Unique Key | 2 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 12/17/2024 | Sample type | Quality Assurance |
| A brief description of the sample | ASTM A325 .625" X 2" HS Cap Screws | The quantity of what the sample constitutes | 291 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Paul |
| Last name of sampler or witnessed by | Farinha | Title of sampler | ASI |
| Telephone number of sampler | 530-401-0199 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | KW Industries | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
|---|---|---|---|
| Heat Number(s) | 1000122173 | Nut Mfg. Lot Number(s) | N/A |
| Washer Mfg. Lot Number(s) | N/A | Bolt Specification | ASTM F3125, A325 |
| Bolt Length(s) | 2" | Nut Specification | N/A |
| Washer Specification | N/A | Finish | HDG - Lubricated |
| Diameter/Size | .625" | Bolt Mfg. Lot Number | W000104060 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | Required | |
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2024-12-11-2-1 ASME B1.2-83r17 (Verified)
DIME Test ID: 2024-12-11-2-2 ASME B1.2-83r17 (Verified)
DIME Test ID: 2024-12-11-2-3 ASME B1.2-83r17 (Verified)
DIME Test ID: 2024-12-11-2-4 ASTM B499-09r21 (Verified)
DIME Test ID: 2024-12-11-2-5 ASTM B499-09r21 (Verified)
DIME Test ID: 2024-12-11-2-6 ASTM B499-09r21 (Verified)
DIME Test ID: 2024-12-11-2-7 ASTM E18-20 (Verified)
DIME Test ID: 2024-12-11-2-8 ASTM E18-20 (Verified)
DIME Test ID: 2024-12-11-2-9 ASTM E18-20 (Verified)