Sample Record
DIME Sample ID 2024-08-08-125
Project Information
| Project Identifiers | Project ID: 995240 DEA: 060X3804 EFIS: 0618000060 |
|---|---|
| DIST-CO-RTE-PM | 06-KER-166-0.0/10.2 |
| Award Date | 02/28/2024 |
| Closeout Date | 01/09/2026 |
| Work Description | COLD PLANE, PLACE HMA AND CONCRETE PAVEMENT, MODIFY DRAINAGE SYSTEM. |
| Location Description | KERN COUNTY IN AND NEAR MARICOPA FROM SOUTH JUNCTION ROUTE 33 TO 2.3 MILES WEST OF SAN EMIGDIO CREEK BRIDGE |
| QA Service Level | 1 (Verified on 04/02/2024) |
Owner Lab
- Precon Products - Simi Valley
Sample Information
| Sample Taken Date | 08/08/2024 | Sample Unique Key | 125 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/08/2024 | Sample type | Quality Control |
| A brief description of the sample | Mix 23-SE-10125 | The quantity of what the sample constitutes | 9 concrete cylinders |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Maximus |
| Last name of sampler or witnessed by | Guillen | Title of sampler | QCM |
| Telephone number of sampler | 8052975145 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Pre-Con Products | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 23-SE-10125 |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 301747 | |
| Concrete batch plant | Builders Ready Mix | The fabricator/manufacturer designation for the sample | |
| A detailed description of where the material sample was collected | Sampled for Delivery Truck | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Submitted Tests
| DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Date Added | Verified? | Release Date | Test Comments | Privacy Level | Actions |
|---|---|---|---|---|---|---|---|---|---|
| 2024-08-08-125-1 | ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete | Brandon Garcia, Precon Products - Simi Valley | 08/08/2024 | 11/26/2024 | No | ||||
| 2024-08-08-125-2 | ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete | Brandon Garcia, Precon Products - Simi Valley | 08/08/2024 | 11/26/2024 | No | ||||
| 2024-08-08-125-3 | ASTM C231-17a: Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method | Brandon Garcia, Precon Products - Simi Valley | 08/08/2024 | 11/26/2024 | No | ||||
| 2024-08-08-125-4 | ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens | Brandon Garcia, Precon Products - Simi Valley | 08/09/2024 | 11/26/2024 | No | ||||
| 2024-08-08-125-5 | ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens | Brandon Garcia, Precon Products - Simi Valley | 08/15/2024 | 11/26/2024 | No | ||||
| 2024-08-08-125-6 | ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens | Brandon Garcia, Precon Products - Simi Valley | 09/05/2024 | 11/26/2024 | No |
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2024-08-08-125-1 ASTM C143-20
DIME Test ID: 2024-08-08-125-2 ASTM C1064-17
DIME Test ID: 2024-08-08-125-3 ASTM C231-17a
DIME Test ID: 2024-08-08-125-4 ASTM C39-21
DIME Test ID: 2024-08-08-125-5 ASTM C39-21
DIME Test ID: 2024-08-08-125-6 ASTM C39-21