Sample Record
Owner Labs
- CT HQ - QASI Sacramento Field Office
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2024-11-26-2
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 1000297 DEA: 010P0704 EFIS: 0124000162 |
|---|---|
| DIST-CO-RTE-PM | 01-MEN-1-82.1/92.9 |
| Award Date | 03/18/2024 |
| Closeout Date | Not set |
| Work Description | Major items of work include traffic control, reconstruct and stabilize roadway, install micropiles, roadway excavation, repair retaining wall, repair viaduct, restore drainage systems, erosion control and additional work as necessary. |
| Location Description | In Mendocino Bounty near Rockport from 9 miles South of Juan Creek Bridge to Juan Creek Bridge. |
| QA Service Level | 1 (Verified on 04/25/2024) |
Sample Information
| Sample Taken Date | 11/26/2024 | Sample Unique Key | 2 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/12/2024 |
| Sample type | Acceptance | A brief description of the sample | A449 and F1554 Fasteners |
| The quantity of what the sample constitutes | 5 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Ken | Last name of sampler or witnessed by | Riley |
| Title of sampler | CALTRANS METS QA INSPECTOR | Telephone number of sampler | 7078286930 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | C&K Johnson | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | S78-026-24 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 2101608 8000019551 136051 | Nut Mfg. Lot Number(s) | W000013557 |
| Washer Mfg. Lot Number(s) | 0224-140 | Bolt Specification | F1554-36 HDG |
| Bolt Length(s) | 6" | Nut Specification | A563 DH HDG |
| Washer Specification | F436 Domestic HDG | Finish | HDG |
| Diameter/Size | 1"x6" | Bolt Mfg. Lot Number | 2101608 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | Wax | |
| Washer Inner Diameter(s) |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2024-11-26-2-1 ASTM B499-09r21 (Verified)
DIME Test ID: 2024-11-26-2-2 ASTM B499-09r21 (Verified)
DIME Test ID: 2024-11-26-2-3 ASTM B499-09r21 (Verified)
DIME Test ID: 2024-11-26-2-4 ASTM E18-20 (Verified)
DIME Test ID: 2024-11-26-2-5 ASTM E18-20 (Verified)
DIME Test ID: 2024-11-26-2-6 ASTM A370-20 (Verified)