Sample Record

Owner Lab

  • CT D05 - Carpinteria Field Laboratory

DIME Sample ID 2024-11-12-27

Project Information

Project IdentifiersProject ID: 994864
DEA: 050N74U4
EFIS: 0522000025
DIST-CO-RTE-PM05-SB-101-9.9/10.6
Award Date07/10/2023
Closeout DateNot set
Work DescriptionSB 101 4D North San Ysidro to Olive Mill
Location DescriptionIn Santa Barbara County in and near Santa Barbara from 0.1 mile south of San Ysidro Road Overcrossing to 0.1 north of Olive Mill Road Overcrossing
QA Service Level1 (Verified on 08/21/2023)

Sample Information

Sample Taken Date11/12/2024 Sample Unique Key27
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/12/2024
Sample typeQuality Assurance A brief description of the sampleCRCP Aggregates
The quantity of what the sample constitutes40 CY From where was the sample collectedSupplier
First name of sampler or witnessed byMike Last name of sampler or witnessed byBennett
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Padaro Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design number231 R
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected16696
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedDischarge from concrete truck into wheelbarrow. Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2024-11-12-27-1ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement ConcreteMichael Bennett, CT D05 - Carpinteria Field Laboratory11/12/2024Michael Bennett
Yes
11/13/2024
2024-11-12-27-2CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure MethodMichael Bennett, CT D05 - Carpinteria Field Laboratory11/12/2024Michael Bennett
Yes
11/13/2024
2024-11-12-27-3CTM 533-June 2010: Method of Test for Ball Penetration in Fresh Portland Cement ConcreteMichael Bennett, CT D05 - Carpinteria Field Laboratory11/12/2024Michael Bennett
Yes
11/13/2024

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-11-12-27-1 ASTM C1064-17 (Verified)
DIME Test ID: 2024-11-12-27-2 CTM 504-June 2010 (Verified)
DIME Test ID: 2024-11-12-27-3 CTM 533-June 2010 (Verified)