Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2017-03-22-7

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 3951
DEA: 07202114
EFIS: 0700020869
DIST-CO-RTE-PM07-LA-710-17.2/26.4
Award Date04/04/2012
Closeout Date06/16/2021
Work DescriptionPAVE ROADWAY WITH LONG LIFE PAVEMENT AND WIDEN ROADWAY AND BRIDGES
Location DescriptionLOS ANGELES COUNTY ON ROUTE 710 AT VARIOUS LOCATIONS FROM LOS ANGELES RIVER BRIDGE TO RAMONA BOULEVARD UNDERCROSSING
QA Service Level1 (Verified on 11/27/2012)

Sample Information

Sample Taken Date03/22/2017 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/04/2017
Sample typeQuality Assurance A brief description of the sampleBarsplice Doublr Barrel Zap Screwlok Coupler
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byPedro Last name of sampler or witnessed byLabrada
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameBarsplice, CMC Rebar Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormN/A Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC Rebar
Coupler ManufacturerBarSplice Intermediate Assembler or FabricatorUnknown
Rebar Size#6 Coupler ModelBarsplice Double Barrel Zap ScrewLok
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)4136 Rebar Heat Number(s)4062265
Rebar Size 2 Not set Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-03-22-7-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory04/05/2017Fred
Yes
04/12/2017Service Splice
2017-03-22-7-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory04/05/2017Fred
Yes
04/12/2017Service Splice
2017-03-22-7-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory04/05/2017Fred
Yes
04/12/2017Service Splice

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-03-22-7-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-03-22-7-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-03-22-7-3 CTM 670-December 2013 (Verified)