Sample Record

Owner Lab

  • CT D06 - Millbrook Field Laboratory

DIME Sample ID 2024-10-29-8

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 995124
DEA: 060X3004
EFIS: 0618000051
DIST-CO-RTE-PM06-FRE-33-69.4/71.5
Award Date02/06/2024
Closeout DateNot set
Work DescriptionREPLACE ROADWAY PAVEMENT.
Location DescriptionFRESNO COUNTY IN AND NEAR FIREBAUGH FROM MORRIS KYLE DRIVE TO LYON AVENUE
QA Service Level1 (Verified on 10/25/2023)

Sample Information

Sample Taken Date10/29/2024 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/30/2024
Sample typeQuality Assurance A brief description of the sample3/4” HMA Aggregate
The quantity of what the sample constitutes0-750 Tons Produced From where was the sample collectedManufacturer
First name of sampler or witnessed byNoah Last name of sampler or witnessed byHunt
Title of samplerSenior Materials Tester Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSanta Fe Winton Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Teichert Santa Fe Winton
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedAutomatic Sampling Device @ Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number3
Sublot number9 Aggregate Mix Number

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2024-10-29-8-1AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)Tomas Silva, CT D06 - Millbrook Field Laboratory10/30/2024Tomas Silva
Yes
10/30/2024
2024-10-29-8-2AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)Tomas Silva, CT D06 - Millbrook Field Laboratory10/30/2024Tomas Silva
Yes
10/30/2024

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-10-29-8-1 AASHTO T27-14 (Verified)
DIME Test ID: 2024-10-29-8-2 AASHTO T176-08 (Verified)