Sample Record

Owner Labs

  • CT SC - 3667 - Crescent City
  • CT D01 - District 1 Materials Laboratory

DIME Sample ID 2024-10-09-45

Project Information

Project IdentifiersProject ID: 215620
DEA: 01436404
EFIS: 0100000193
DIST-CO-RTE-PM01-DN-101-35.8/36.5
Award Date07/11/2022
Closeout DateNot set
Work DescriptionDr. Fine Bridge Replacement
Location DescriptionDR. FINE BRIDGE REPLACEMENT FROM LAKE EARL DR TO S FRED D. HAIGHT DR ON HWY 101 ACROSS SMITH RIVER.
QA Service Level1 (Verified on 03/26/2021)

Sample Information

Sample Taken Date10/09/2024 Sample Unique Key45
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing10/09/2024
Sample typeQuality Assurance A brief description of the sampleConcrete for abutment cidh
The quantity of what the sample constitutes~11CY of SR 3/8s CIDH From where was the sample collectedJob Site
First name of sampler or witnessed byBarrett Last name of sampler or witnessed byUpdegraff
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID2024-10-09
The fabricator/manufacturer/facility nameTidewater Contractors Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameDr. Fine Bridge Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberSR 3/8s CIDH
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected61515
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedFrom rebar cage, inside CIDH Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2024-10-09-45-1CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete CylindersJamie Kelley, CT D01 - District 1 Materials Laboratory10/16/202410/16/2024
Yes
10/16/202410/16/24 7 Day Break, 1 CylinderPublic - Test Data Visible
2024-10-09-45-2CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete CylindersTom Brown, CT D01 - District 1 Materials Laboratory11/06/202411/06/2024
Yes
11/06/202411/6/24 28 Day Break, 3 CylindersPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-10-09-45-1 CTM 521-June 2012 (Verified)
DIME Test ID: 2024-10-09-45-2 CTM 521-June 2012 (Verified)