Sample Record

DIME Sample ID 2017-02-08-9

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211371
DEA: 120H2434
EFIS: 1214000038
DIST-CO-RTE-PM12-LA,ORA-91-R20.6/R20.7,R0.0/R2.8
Award Date06/15/2016
Closeout Date08/27/2018
Work DescriptionINSTALL FIBER OPTIC CABLE & CCTVS
Location DescriptionORANGE AND LOS ANGELES COUNTIES IN LA PALMA, BUENA PARK AND CERRITOS FROM 0.1 MILE WEST OF LOS ANGELES COUNTY LINE TO STANTON AVENUE UNDERCROSSING
QA Service Level1 (Verified on 09/01/2016)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date02/08/2017 Sample Unique Key9
Date that the sample was received by the laboratory/organization performing the testing02/15/2017 Sample typeQuality Assurance
A brief description of the sampleFlash Welded Rebar Hoops The quantity of what the sample constitutes4
From where was the sample collectedFabricator First name of sampler or witnessed byWilliam
Last name of sampler or witnessed byClifford Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameUnknown
Transportation Laboratory (TL) NumberC953748 Inspector Lot Number from the Transportation Laboratory (TL) FormL7800417
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateService Rebar Heat Number(s)PL16108469
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size5
Diameter of Hoop3'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerMartinez Steel
Welding CompanyMartinez Steel Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2017-02-08-9-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory02/15/201702/15/2017
Yes
02/22/2017Service SplicePublic - Test Data Visible
2017-02-08-9-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory02/15/201702/15/2017
Yes
02/22/2017Bar Broke; OK NeckingPublic - Test Data Visible
2017-02-08-9-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory02/15/201702/15/2017
Yes
02/22/2017Service SplicePublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-02-08-9-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-02-08-9-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-02-08-9-3 CTM 670-December 2013 (Verified)