Sample Record

DIME Sample ID 2024-08-29-60

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 994319
DEA: 023J7104
EFIS: 0222000076
DIST-CO-RTE-PM02-PLU-89-8.7/12.9
Award Date11/29/2022
Closeout Date04/21/2025
Work DescriptionPLACE HOT MIX ASPHALT (TYPE A) AND REPLACE AC SURFACING.
Location DescriptionPLUMAS COUNTY NEAR CRESCENT MILLS FROM ROUTE 70 TO 0.7 MILE SOUTH OF DIXIE CANYON ROAD
QA Service Level1 (Verified on 10/26/2022)

Owner Lab

  • CT D02 - Redding Northern Regional Laboratory

Sample Information

Sample Taken Date08/29/2024 Sample Unique Key60
Date that the sample was received by the laboratory/organization performing the testing09/03/2024 Sample typeAcceptance
A brief description of the sampleShoulder Backing The quantity of what the sample constitutes2 bags
From where was the sample collectedManufacturer First name of sampler or witnessed byCGI
Last name of sampler or witnessed byCGI Title of samplerQC
Telephone number of sampler Laboratory sample identificationD79702
Linked DIME Sample ID The fabricator/manufacturer/facility nameDig It Construction – Sierra Cascade Aggregate and Asphalt Products (Chester, CA)
Transportation Laboratory (TL) Number857951 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Sierra Cascade "Dig It"
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2024-08-29-60-1CTM 301-March 2000: Method for Determining the Resistance "R" Value of Treated and Untreated Bases, Subbases, and Basement Soils by the StabilometerJosh Ferency, CT D02 - Redding Northern Regional Laboratory09/25/202409/25/2024
Yes
09/26/2024R=83Public - Test Data Visible
2024-08-29-60-2CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)Josh Ferency, CT D02 - Redding Northern Regional Laboratory09/23/202409/25/2024
Yes
09/26/2024LL=NP, PL=NP, PI=NPPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-08-29-60-1 CTM 301-March 2000 (Verified)
DIME Test ID: 2024-08-29-60-2 CTM 204-June 2010 (Verified)