Sample Record

DIME Sample ID 2017-02-08-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 210808
DEA: 020E0904
EFIS: 0200000016
DIST-CO-RTE-PM02-SHA-5-R29.3/R31.1,R45.0/R45.8
Award Date02/03/2016
Closeout Date10/21/2020
Work DescriptionREPLACE BRIDGE, REALIGN ROADWAY AND SEISMIC RETROFIT
Location DescriptionIN SHASTA COUNTY ABT 8 MI N OF SHASTA LAKE CTY AND NEAR LAKEHEAD FRM TURNTABLE BAY O/C TO 0.1 MI N OF O'BRIEN SRRA & FRM 0.4 MI S TO 0.3 MI N OF DOG CREEK BRIDGE.
QA Service Level1 (Verified on 09/23/2015)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date02/08/2017 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing02/08/2017 Sample typeQuality Assurance
A brief description of the sampleStainless Steel The quantity of what the sample constitutes2
From where was the sample collectedFabricator First name of sampler or witnessed byCorey
Last name of sampler or witnessed byGardner Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameContractor Materials Company
Transportation Laboratory (TL) NumberC704031 Inspector Lot Number from the Transportation Laboratory (TL) FormNA
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNorth American Stainless
Coupler ManufacturerNorth American Stainless Intermediate Assembler or FabricatorUnknown
Rebar Size#8 Coupler ModelThreaded stainless Coupler
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)M9P1 Rebar Heat Number(s)Y1E0
Rebar Size 2 Not set Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2017-02-08-1-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory02/10/201702/10/2017
Yes
03/01/2017Pull out of CouplerPublic - Test Data Visible
2017-02-08-1-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory02/10/201702/10/2017
Yes
03/01/2017Pull out of couplerPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-02-08-1-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-02-08-1-2 CTM 670-December 2013 (Verified)