Sample Record

DIME Sample ID 2024-09-20-8

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 1000555
DEA: 101T4304
EFIS: 1024000258
DIST-CO-RTE-PM10---
Award DateNot set
Closeout DateNot set
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 09/09/2024)

Owner Lab

  • CT HQ - QASI Sacramento Field Office

Sample Information

Sample Taken Date09/20/2024 Sample Unique Key8
Date that the sample was received by the laboratory/organization performing the testing09/25/2024 Sample typeVerification
A brief description of the sampleDouble Barrel ZAP Screwlok Standard Coupler - Operator Pre-Qualification - German Ceres The quantity of what the sample constitutes4
From where was the sample collectedFabricator First name of sampler or witnessed byLevi
Last name of sampler or witnessed byPivoda Title of samplerAssociate Steel Inspector
Telephone number of sampler19152961871 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCamblin Steel
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormS88-920-24
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateService Material Standard CodeASTM A615
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerBarSplice Products Inc Intermediate Assembler or Fabricator
Rebar Size#5 Coupler ModelDouble Barrel ZAP Screwlok Standard Coupler
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)3354 Rebar Heat Number(s)3500039115
Rebar Size 2 5 Coupler Unique IDSB-17-02

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2024-09-20-8-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory10/01/202409/30/2024
Yes
10/01/2024Service SplicePublic - Test Data Visible
2024-09-20-8-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory10/01/202409/30/2024
Yes
10/01/2024Service SplicePublic - Test Data Visible
2024-09-20-8-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory10/01/202409/30/2024
Yes
10/01/2024Service SplicePublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-09-20-8-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-09-20-8-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-09-20-8-3 CTM 670-December 2013 (Verified)