Sample Record

DIME Sample ID 2017-01-26-5

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 210785
DEA: 07255104
EFIS: 0700000465
DIST-CO-RTE-PM07-LA-60-R23.8/R24.5
Award Date01/08/2016
Closeout Date06/25/2019
Work DescriptionCONSTRUCT WESTBOUND ONRAMP AND CONCRETE PAVEMENT
Location DescriptionLA COUNTY, IN DIMOND BAR ANDINDUSTRY AT GRAND AVENUE/SR 57/60 IC
QA Service Level1 (Verified on 02/29/2016)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date01/26/2017 Sample Unique Key5
Date that the sample was received by the laboratory/organization performing the testing01/30/2017 Sample typeQuality Assurance
A brief description of the sampleFlash Welded Rebar Hoops The quantity of what the sample constitutes4
From where was the sample collectedFabricator First name of sampler or witnessed byDave
Last name of sampler or witnessed byWeeks Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameTNT Rebar
Transportation Laboratory (TL) NumberC953652 Inspector Lot Number from the Transportation Laboratory (TL) FormL7900617
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateService Rebar Heat Number(s)6502310502
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size4
Diameter of Hoop2'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerTNT
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2017-01-26-5-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory01/31/201701/31/2017
Yes
02/07/2017Bar Broke; OK NeckingPublic - Test Data Visible
2017-01-26-5-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory01/31/201701/31/2017
Yes
02/07/2017Bar Broke in Heat Affected AreaPublic - Test Data Visible
2017-01-26-5-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory01/31/201701/31/2017
Yes
02/07/2017Bar Broke; OK NeckingPublic - Test Data Visible
2017-01-26-5-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory01/31/201701/31/2017
Yes
02/07/2017Bar Broke in Heat Affected AreaPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-01-26-5-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-01-26-5-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-01-26-5-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-01-26-5-4 CTM 670-December 2013 (Verified)