Sample Record
Owner Lab
- CT HQ - QASI Bay Area Field Office
DIME Sample ID 2019-06-11-5
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 212824 DEA: 051C3704 EFIS: 0512000135 |
|---|---|
| DIST-CO-RTE-PM | 05-SLO-101-16.4 |
| Award Date | 11/20/2018 |
| Closeout Date | 08/23/2021 |
| Work Description | PISMO CREEK SCOUR REPAIR PROJECT (BR 49-0015K) |
| Location Description | IN SAN LUIS OBISPO COUNTY IN PISMO AT PISMO CREEK BRIDGE |
| QA Service Level | 1 (Verified on 01/29/2019) |
Sample Information
| Sample Taken Date | 06/11/2019 | Sample Unique Key | 5 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/12/2019 |
| Sample type | Quality Assurance | A brief description of the sample | Flash Welded Rebar Hoops |
| The quantity of what the sample constitutes | 128 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Carpenter |
| Title of sampler | QA | Telephone number of sampler | 415-608-1742 |
| Laboratory sample identification | H02 | Linked DIME Sample ID | 2019-06-11-5 |
| The fabricator/manufacturer/facility name | Harris Rebar | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B24-008-19 | Structure unique identifier | |
| Structure name | Bridge Bent Retro | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Service | Rebar Heat Number(s) | 113522 |
| Hoop Manufacturer Lot Number(s) | H02 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | 6 |
| Diameter of Hoop | 2'-6" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | Evraz |
| Welding Company | Harris | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2019-06-11-5-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-06-11-5-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-06-11-5-3 CTM 670-December 2013 (Verified)