Sample Record

Owner Labs

  • CT HQ - QASI Sacramento Field Office
  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2026-04-13-4

Project Information

Project IdentifiersProject ID: 1001469
DEA: 120K62U4
EFIS: 1224000090
DIST-CO-RTE-PM12-ORA, -5-R25.8/30.3
Award Date11/12/2025
Closeout DateNot set
Work DescriptionCONST BRIDGE, RW, SW, PAVEMENT, DRAINAGE, AND ELECTRICAL SYSTEMS.
Location DescriptionORANGE COUNTY IN IRVINE AND TUSTIN FROM YALE AVENUE OVERCROSSING TO ROUTE 5/55 SEPARATION
QA Service Level1 (Verified on 08/13/2025)

Sample Information

Sample Taken Date04/13/2026 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing04/22/2026
Sample typeQuality Assurance A brief description of the sample#7 rebar Gr60 A706 6'-6" hoops
The quantity of what the sample constitutes218 pcs From where was the sample collectedFabricator
First name of sampler or witnessed byJoaquin Last name of sampler or witnessed byMoreno
Title of samplerQuality Assurance Inspector Telephone number of sampler9095268064
Laboratory sample identification Linked DIME Sample ID2026-04-13-4
The fabricator/manufacturer/facility nameMartines Steel Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL161-025-26 Structure unique identifier
Structure nameBridge Bid Item171 - BAR REINFORCING STEEL (BRIDGE)

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)381924
Hoop Manufacturer Lot Number(s)Lots 1 and 2 Material Standard CodeASTM A706
Material Grade60 Rebar Size#7
Diameter of Hoop6'-6" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCascade Steel
Welding CompanyMartinez Steel Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2026-04-13-4-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Andrew Auvinen, CT HQ - Sacramento Structural Materials Testing Laboratory04/28/202604/28/2026
Yes
04/28/2026 

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2026-04-13-4-1 CTM 670-December 2013 (Verified)