Sample Record

DIME Sample ID 2017-12-06-3

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 212674
DEA: 044H3104
EFIS: 0413000207
Permit Numbers: 0417NOP1833 0417NDP2004
DIST-CO-RTE-PM04-SM-101-0.47/0.47
Award Date08/28/2017
Closeout Date07/19/2019
Work DescriptionOvercrossing Structure with pier in median, reconfigured median barrier, and relocated overhead sign structure.
Location Descriptionroute 101, East Palo Alto
QA Service Level2 (Verified on 12/11/2017)

Owner Lab

  • CT - Unassigned/General Field Laboratory

Sample Information

Sample Taken Date12/06/2017 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing12/06/2017 Sample typeQuality Assurance
A brief description of the sampleFlash Welded Rebar The quantity of what the sample constitutes4
From where was the sample collectedSource First name of sampler or witnessed byTory
Last name of sampler or witnessed byMcLaurin Title of samplerQA Inspector
Telephone number of sampler6616185971 Laboratory sample identificationUnknown
Linked DIME Sample ID2017-12-06-3 The fabricator/manufacturer/facility nameRKR Welding
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormL67-286-17
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)65028351
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size7
Diameter of Hoop5'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerGerdau
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2017-12-06-3-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory12/11/201712/11/2017
Yes
12/19/2017Bar Broke; OK NeckingPublic - Test Data Visible
2017-12-06-3-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory12/11/201712/11/2017
Yes
12/19/2017Bar Broke; OK NeckingPublic - Test Data Visible
2017-12-06-3-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory12/11/201712/11/2017
Yes
12/19/2017Bar Broke; OK NeckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-12-06-3-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-12-06-3-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-12-06-3-3 CTM 670-December 2013 (Verified)