Sample Record

DIME Sample ID 2025-07-14-139

Project Information

Project IdentifiersProject ID: 993825
DEA: 040Q30U4
EFIS: 0420000235
COOP: 042830A3,042830A4
DIST-CO-RTE-PM04-ALA,CC-680-R11.0/R21.9,R0.0/R0.9
Award Date11/23/2022
Closeout DateNot set
Work DescriptionPRECAST CONC PVMT, ELECTRONIC TOLL SYSTEM, JPCP, CB & STRUCTURAL CONC
Location DescriptionALAMEDA AND CONTRA COSTA COUNTIES AT SUNOL AND IN SAN RAMON BETWEEN 0.4 MILE SOUTH OF CALAVERAS ROAD UNDERCROSSING TO 0.9 MILE NORTH OF ALCOSTA BOULEVARD OVERCROSSING
QA Service Level1 (Verified on 05/11/2022)

Owner Labs

  • BSK Associates
  • CT D04 - Hayward DME / District Laboratory

Sample Information

Sample Taken Date07/14/2025 Sample Unique Key139
Date that the sample was received by the laboratory/organization performing the testing07/25/2025 Sample typeProduction Start-Up
A brief description of the sample1/2" HMA w/25% RAP The quantity of what the sample constitutes16 boxes HMA
From where was the sample collectedJob Site First name of sampler or witnessed byBhalinder
Last name of sampler or witnessed byPandher Title of sampler
Telephone number of sampler Laboratory sample identificationD04-SE-25-043
Linked DIME Sample ID2025-07-14-138 The fabricator/manufacturer/facility nameVulcan Pleasanton
Transportation Laboratory (TL) NumberCPL071425 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number320302W
Binder content (%)0.0 Virgin binder PG
Design binder PG Binder Supplier
RAP content (%)25 WMA Additives
Antistrip type

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2025-07-14-139-1AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)Nicholas Shelly - BSK, BSK Associates10/30/202511/05/2025
No
Average Bulk Specific Gravity= 2.420
2025-07-14-139-2AASHTO T269-24E25: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)Nicholas Shelly - BSK, BSK Associates10/30/202511/05/2025
No
Gmm=2.495, Average Percent Air Voids=3.0%
2025-07-14-139-3AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)Trevor Hamilton - BSK, BSK Associates10/30/202511/05/2025
No
Wet=176.7 psi, Dry=214.3 psi, TSR=83%
2025-07-14-139-4CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix AsphaltTrevor Hamilton - BSK, BSK Associates10/30/202511/05/2025
No
H.W. > 15,000 passes, SIP > 12,500 passes

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2025-07-14-139-1 AASHTO T275-07r12
DIME Test ID: 2025-07-14-139-2 AASHTO T269-24E25
DIME Test ID: 2025-07-14-139-3 AASHTO T283-14
DIME Test ID: 2025-07-14-139-4 CTM 389-19