Sample Record
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2017-04-13-9
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 8196 DEA: 59912684 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | |
| Location Description | |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 04/13/2017 | Sample Unique Key | 9 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/28/2017 |
| Sample type | Quality Assurance | A brief description of the sample | Prestressing Strand |
| The quantity of what the sample constitutes | 50 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Dan | Last name of sampler or witnessed by | Hiranaga |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Sumiden Wire | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM4 - Prestressing Strand | Comments | Unknown |
|---|---|---|---|
| Reel/Coil/Pack Number(s) | Number of Coils | 50 | |
| Group Number | 10858 | Strand Diameter | .5 in |
| Grade | 270 | Strand Specification | ASTM A 416 |
| Heat Number(s) | S0290090 S0290091 S0290092 S0290660 S0290662 S0290665 S0290667 S0290668 S0290682 S0505217 S0505517 S0505617 S0505917 S0522316 S0522416 S0522816-2 S0523216-2 S0523316-2 S0523616 S0533517 S0533617 | Mfg. Lot Number(s) | na |
| Manufacturer(s) | Sumiden Wire |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2017-04-13-9-1 ASTM A416-15 (Verified)
DIME Test ID: 2017-04-13-9-2 ASTM A416-15 (Verified)
DIME Test ID: 2017-04-13-9-3 ASTM A416-15 (Verified)
DIME Test ID: 2017-04-13-9-4 ASTM A416-15 (Verified)
DIME Test ID: 2017-04-13-9-5 ASTM A416-15 (Verified)
DIME Test ID: 2017-04-13-9-6 ASTM A416-15 (Verified)
DIME Test ID: 2017-04-13-9-7 ASTM A416-15 (Verified)
DIME Test ID: 2017-04-13-9-8 ASTM A416-15 (Verified)
DIME Test ID: 2017-04-13-9-9 ASTM A416-15 (Verified)
DIME Test ID: 2017-04-13-9-10 ASTM A416-15 (Verified)
DIME Test ID: 2017-04-13-9-11 ASTM A416-15 (Verified)
DIME Test ID: 2017-04-13-9-12 ASTM A416-15 (Verified)
DIME Test ID: 2017-04-13-9-13 ASTM A416-15 (Verified)
DIME Test ID: 2017-04-13-9-14 ASTM A416-15 (Verified)
DIME Test ID: 2017-04-13-9-15 ASTM A416-15 (Verified)
DIME Test ID: 2017-04-13-9-16 ASTM A416-15 (Verified)
DIME Test ID: 2017-04-13-9-17 ASTM A416-15 (Verified)
DIME Test ID: 2017-04-13-9-18 ASTM A416-15 (Verified)
DIME Test ID: 2017-04-13-9-19 ASTM A416-15 (Verified)
DIME Test ID: 2017-04-13-9-20 ASTM A416-15 (Verified)
DIME Test ID: 2017-04-13-9-21 ASTM A416-15 (Verified)
DIME Test ID: 2017-04-13-9-22 ASTM A416-15 (Verified)
DIME Test ID: 2017-04-13-9-23 ASTM A416-15 (Verified)
DIME Test ID: 2017-04-13-9-24 ASTM A416-15 (Verified)
DIME Test ID: 2017-04-13-9-25 ASTM A416-15 (Verified)
DIME Test ID: 2017-04-13-9-26 ASTM A416-15 (Verified)
DIME Test ID: 2017-04-13-9-27 ASTM A416-15 (Verified)
DIME Test ID: 2017-04-13-9-28 ASTM A416-15 (Verified)
DIME Test ID: 2017-04-13-9-29 ASTM A416-15 (Verified)
DIME Test ID: 2017-04-13-9-30 ASTM A416-15 (Verified)
DIME Test ID: 2017-04-13-9-31 ASTM A416-15 (Verified)
DIME Test ID: 2017-04-13-9-32 ASTM A416-15 (Verified)