Sample Record
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2023-12-18-26
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 215677 DEA: 044G0804 EFIS: 0412000332 COOP: 042676 |
|---|---|
| DIST-CO-RTE-PM | 04-SOL-80-R10.4/30.2 |
| Award Date | 01/18/2022 |
| Closeout Date | Not set |
| Work Description | Highway widening, overhead signs, and electronic toll system. |
| Location Description | In Solano County in Fairfield and Vacaville from 1.0 mile west of Red Top Road Undercrossing to 0.4 mile east of Leisure Town Road Overcrossing. |
| QA Service Level | 1 (Verified on 04/11/2022) |
Sample Information
| Sample Taken Date | 12/18/2023 | Sample Unique Key | 26 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/27/2023 |
| Sample type | Quality Assurance | A brief description of the sample | Fastener Assembly |
| The quantity of what the sample constitutes | 275 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Oscar | Last name of sampler or witnessed by | Vizcaino |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Madison, IL | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 10851370 234284 42316930 | Nut Mfg. Lot Number(s) | 39225-234284 |
| Washer Mfg. Lot Number(s) | 0623-772 | Bolt Specification | A325 |
| Bolt Length(s) | 2 | Nut Specification | A563 |
| Washer Specification | F436 | Finish | MG |
| Diameter/Size | 7/8 | Bolt Mfg. Lot Number | 39192-10851370 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Submitted Tests
Go to page:
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2023-12-18-26-1 ASTM F606-21 (Verified)
DIME Test ID: 2023-12-18-26-2 ASME B1.2-83r17 (Verified)
DIME Test ID: 2023-12-18-26-3 ASME B1.2-83r17 (Verified)
DIME Test ID: 2023-12-18-26-4 ASTM B499-09r21 (Verified)
DIME Test ID: 2023-12-18-26-5 ASTM B499-09r21 (Verified)
DIME Test ID: 2023-12-18-26-6 ASTM B499-09r21 (Verified)
DIME Test ID: 2023-12-18-26-7 ASTM B499-09r21 (Verified)
DIME Test ID: 2023-12-18-26-8 ASTM B499-09r21 (Verified)
DIME Test ID: 2023-12-18-26-9 ASTM B499-09r21 (Verified)
DIME Test ID: 2023-12-18-26-10 ASTM E18-20 (Verified)
DIME Test ID: 2023-12-18-26-11 ASTM E18-20 (Verified)
DIME Test ID: 2023-12-18-26-12 ASTM E18-20 (Verified)
DIME Test ID: 2023-12-18-26-13 ASTM E18-20 (Verified)