Sample Record
DIME Sample ID 2021-06-30-28
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 214951 DEA: 120K0234 EFIS: 1214000100 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-5-17.1/18.9 |
| Award Date | 09/23/2020 |
| Closeout Date | 02/09/2026 |
| Work Description | South County Improvement Project (Phase 3 - El Toro/Alicia) WIDEN FREEWAY AND BRIDGES, RECONSTRUCT BRIDGE AND WALLS. |
| Location Description | ORANGE COUNTY IN MISSION VIEJO, LAGUNA HILLS, LAGUNA WOODS AND LAKE FOREST FROM 0.4 MILE SOUTH OF ALICIA PARKWAY OVERCROSSING TO 0.2 MILE NORTH OF EL TORO ROAD UNDERCROSSING |
| QA Service Level | 1 (Verified on 10/01/2020) |
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Information
| Sample Taken Date | 06/30/2021 | Sample Unique Key | 28 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/12/2021 | Sample type | Quality Assurance |
| A brief description of the sample | 2" x 50" | The quantity of what the sample constitutes | 86 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Oscar |
| Last name of sampler or witnessed by | Vizcaino | Title of sampler | |
| Telephone number of sampler | 6787558969 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Madden Bolt | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 58047362, 201699 | Nut Mfg. Lot Number(s) | DECZ |
| Washer Mfg. Lot Number(s) | 1120-640 | Bolt Specification | ASTM F1554 |
| Bolt Length(s) | 50" | Nut Specification | A194-2H/A563-DH |
| Washer Specification | F436 | Finish | A153/A123 HDG |
| Diameter/Size | 2" | Bolt Mfg. Lot Number | 58047362 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2021-06-30-28-1 ASTM A370-15 (Verified)
DIME Test ID: 2021-06-30-28-2 ASTM A370-15 (Verified)
DIME Test ID: 2021-06-30-28-3 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-06-30-28-4 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-06-30-28-5 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-06-30-28-6 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-06-30-28-7 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-06-30-28-8 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-06-30-28-9 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-06-30-28-10 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-06-30-28-11 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-06-30-28-12 ASTM B499-14 (Verified)
DIME Test ID: 2021-06-30-28-13 ASTM B499-14 (Verified)
DIME Test ID: 2021-06-30-28-14 ASTM B499-14 (Verified)
DIME Test ID: 2021-06-30-28-15 ASTM B499-14 (Verified)
DIME Test ID: 2021-06-30-28-16 ASTM B499-14 (Verified)
DIME Test ID: 2021-06-30-28-17 ASTM B499-14 (Verified)
DIME Test ID: 2021-06-30-28-18 ASTM B499-14 (Verified)
DIME Test ID: 2021-06-30-28-19 ASTM B499-14 (Verified)
DIME Test ID: 2021-06-30-28-20 ASTM B499-14 (Verified)
DIME Test ID: 2021-06-30-28-21 ASTM E18-15 (Verified)
DIME Test ID: 2021-06-30-28-22 ASTM E18-15 (Verified)
DIME Test ID: 2021-06-30-28-23 ASTM E18-15 (Verified)
DIME Test ID: 2021-06-30-28-24 ASTM E18-15 (Verified)