Sample Record
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2020-08-10-4
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 77777 DEA: CHEM-STOCK EFIS: CHEM-STOCK |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for Chem Lab stock material. Object Code: 1025. J2 DEA: 912680. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 08/10/2020 | Sample Unique Key | 4 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/19/2020 |
| Sample type | Quality Assurance | A brief description of the sample | High Strength Fastener Assemblies |
| The quantity of what the sample constitutes | 941 bolts and nuts, 1882 washers | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Craig | Last name of sampler or witnessed by | Hager |
| Title of sampler | QA Inspector | Telephone number of sampler | 925-899-1184 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | UIS Lindon UT | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B29-040-20 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | TT0130553 |
|---|---|---|---|
| Heat Number(s) | bolt 10638100 nut 6214953302 washer 9418013 | Nut Mfg. Lot Number(s) | 30717-6214953302 |
| Washer Mfg. Lot Number(s) | D6918 | Bolt Specification | A325 |
| Bolt Length(s) | 5" | Nut Specification | A563-DH |
| Washer Specification | F436 | Finish | MG |
| Diameter/Size | 1" | Bolt Mfg. Lot Number | L012P1 |
| Rocap Test Requirement(s) | Yes | Lubricant Requirements(s) | None |
| Washer Inner Diameter(s) |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2020-08-10-4-1 ASTM F606-14a (Verified)
DIME Test ID: 2020-08-10-4-2 ASTM F606-14a (Verified)
DIME Test ID: 2020-08-10-4-3 ASTM F606-14a (Verified)
DIME Test ID: 2020-08-10-4-4 ASTM F606-14a (Verified)
DIME Test ID: 2020-08-10-4-5 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-08-10-4-6 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-08-10-4-7 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-08-10-4-8 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-08-10-4-9 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-08-10-4-10 ASTM B499-14 (Verified)
DIME Test ID: 2020-08-10-4-11 ASTM B499-14 (Verified)
DIME Test ID: 2020-08-10-4-12 ASTM B499-14 (Verified)
DIME Test ID: 2020-08-10-4-13 ASTM B499-14 (Verified)
DIME Test ID: 2020-08-10-4-14 ASTM B499-14 (Verified)
DIME Test ID: 2020-08-10-4-15 ASTM B499-14 (Verified)
DIME Test ID: 2020-08-10-4-16 ASTM B499-14 (Verified)
DIME Test ID: 2020-08-10-4-17 ASTM B499-14 (Verified)
DIME Test ID: 2020-08-10-4-18 ASTM B499-14 (Verified)
DIME Test ID: 2020-08-10-4-19 ASTM B499-14 (Verified)
DIME Test ID: 2020-08-10-4-20 ASTM B499-14 (Verified)
DIME Test ID: 2020-08-10-4-21 ASTM B499-14 (Verified)
DIME Test ID: 2020-08-10-4-22 ASTM B499-14 (Verified)
DIME Test ID: 2020-08-10-4-23 ASTM B499-14 (Verified)
DIME Test ID: 2020-08-10-4-24 ASTM B499-14 (Verified)
DIME Test ID: 2020-08-10-4-25 ASTM E18-15 (Verified)
DIME Test ID: 2020-08-10-4-26 ASTM E18-15 (Verified)
DIME Test ID: 2020-08-10-4-27 ASTM E18-15 (Verified)