Sample Record
Owner Lab
- CT HQ - Sacramento Cement Testing Laboratory
DIME Sample ID 2019-01-24-2
Project Information
| Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 01/24/2019 | Sample Unique Key | 2 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/24/2019 |
| Sample type | Proficiency | A brief description of the sample | Type I/II |
| The quantity of what the sample constitutes | 1 box | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Unknown | Last name of sampler or witnessed by | Unknown |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | CM198212 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | CCRL | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | Cementitious | Brand | CCRL |
|---|---|---|---|
| Mill | CCRL | Type of Cementitious Material | Type II Cement |
Submitted Tests
| DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Date Added | Verified? | Release Date | Test Comments | Privacy Level | Actions |
|---|---|---|---|---|---|---|---|---|---|
| 2019-01-24-2-5 | ASTM C151-15: Standard Test Method for Autoclave Expansion of Hydraulic Cement | Stephen Donnelly, CT HQ - Sacramento Cement Testing Laboratory | 02/25/2019 | No | |||||
| 2019-01-24-2-13 | ASTM C266-15: Standard Test Method for Time of Setting of Hydraulic-Cement Paste by Gillmore Needles | Stephen Donnelly, CT HQ - Sacramento Cement Testing Laboratory | 02/27/2019 | No |
Go to page:
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2019-01-24-2-2 ASTM C109-11
DIME Test ID: 2019-01-24-2-3 ASTM C109-11
DIME Test ID: 2019-01-24-2-6 ASTM C185-15a
DIME Test ID: 2019-01-24-2-8 ASTM C191-13
DIME Test ID: 2019-01-24-2-9 ASTM C204-11
DIME Test ID: 2019-01-24-2-10 ASTM C430-8
DIME Test ID: 2019-01-24-2-7 ASTM C187-16
DIME Test ID: 2019-01-24-2-4 ASTM C109-11
DIME Test ID: 2019-01-24-2-11 ASTM C451-13
DIME Test ID: 2019-01-24-2-12 ASTM C1038-14b
DIME Test ID: 2019-01-24-2-5 ASTM C151-15
DIME Test ID: 2019-01-24-2-13 ASTM C266-15