Sample Record
Owner Lab
- CT HQ - QASI Los Angeles Field Office
DIME Sample ID 2019-01-15-2
Project Information
Project Identifiers | Project ID: 3807 DEA: 07121844 EFIS: 0700000117 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-42.8/47.3 |
Award Date | 12/06/2010 |
Closeout Date | 06/30/2021 |
Work Description | CONSTRUCT HOV LANES, RETAINING WALLS AND SOUND WALLS. |
Location Description | LOS ANGELES COUNTY IN LOS ANGELES, GLENDALE, AND BURBANK FROM ROUTE 5/134 SEPARATION TO MAGNOLIA BOULEVARD OVERCROSSING |
QA Service Level | 1 (Verified on 02/23/2012) |
Sample Information
Sample Taken Date | 01/15/2019 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 01/17/2019 |
Sample type | Quality Assurance | A brief description of the sample | ASTM A325 3/4 - 4" |
The quantity of what the sample constitutes | 135 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Arthur | Last name of sampler or witnessed by | Peterson |
Title of sampler | QA Inspector | Telephone number of sampler | 707-342-8602 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Industrial Bolt and Supply | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L110-005-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | RC0033427 |
---|---|---|---|
Heat Number(s) | 10514140 | Nut Mfg. Lot Number(s) | 29387-S |
Washer Mfg. Lot Number(s) | D5483 | Bolt Specification | ASTM A325 |
Bolt Length(s) | 4" | Nut Specification | ASTM A563 |
Washer Specification | ASTM F436 | Finish | Galvanized |
Diameter/Size | 3/4" x 4" | Bolt Mfg. Lot Number | BG1058 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Submitted Tests
Go to page:
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2019-01-15-2-1 ASTM F606-14a (Verified)
DIME Test ID: 2019-01-15-2-2 ASTM F606-14a (Verified)
DIME Test ID: 2019-01-15-2-3 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-01-15-2-4 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-01-15-2-5 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-01-15-2-6 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-01-15-2-7 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-01-15-2-8 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-01-15-2-9 ASTM B499-14 (Verified)
DIME Test ID: 2019-01-15-2-10 ASTM B499-14 (Verified)
DIME Test ID: 2019-01-15-2-11 ASTM B499-14 (Verified)
DIME Test ID: 2019-01-15-2-12 ASTM B499-14 (Verified)
DIME Test ID: 2019-01-15-2-13 ASTM B499-14 (Verified)
DIME Test ID: 2019-01-15-2-14 ASTM B499-14 (Verified)
DIME Test ID: 2019-01-15-2-15 ASTM B499-14 (Verified)
DIME Test ID: 2019-01-15-2-16 ASTM B499-14 (Verified)
DIME Test ID: 2019-01-15-2-17 ASTM B499-14 (Verified)
DIME Test ID: 2019-01-15-2-18 ASTM E18-15 (Verified)
DIME Test ID: 2019-01-15-2-19 ASTM E18-15 (Verified)