Sample Record
Owner Lab
- Vulcan Materials Company - Pleasanton
DIME Sample ID 2019-01-04-3
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 01/04/2019 | Sample Unique Key | 3 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 01/10/2019 | Sample type | Quality Control |
| A brief description of the sample | JMF 1/2 Aggregate Qualities | The quantity of what the sample constitutes | 1 |
| From where was the sample collected | Source | First name of sampler or witnessed by | David |
| Last name of sampler or witnessed by | Ruedi | Title of sampler | Unknown |
| Telephone number of sampler | 9252603017 | Laboratory sample identification | Unknown |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | Vulcan Materials - Pleasanton |
| Transportation Laboratory (TL) Number | Unknown | Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-01-0010::CALMAT/PLEASANTON |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
| The plant number | Unknown | A detailed description of where the material sample was collected | Unknown |
| Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 1/2 inch |
| The concrete mix design number | Unknown | Lot number | 1 |
| Sublot number | 1 | Aggregate Mix Number | Not set |
JMF Information
| HMA Design ID | JMF3512-2019-67-Test | Date Created | 01/28/2019 |
|---|---|---|---|
| Submittal |
Show (8)
JMF3511-208-2019-69 Submittal In Progress JMF3511-208-2019-71 Submittal Completeness Review Failed JMF3511-208-2019-72 Submittal Completeness Review Failed JMF3511-208-2019-113 Submittal In Progress JMF3511-208-2020-220 Submittal In Progress JMF3511-208-2021-6 Submittal Accepted for Verification| JMF3513-2021-6 JMF3511-208-2021-8 Submittal Rejected For Use| JMF3513-2021-13 JMF3511-208-2021-16 Submittal Completeness in Review |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2019-01-04-3-2 AASHTO T209-12 (Verified)
DIME Test ID: 2019-01-04-3-3 AASHTO T27-14 (Verified)
DIME Test ID: 2019-01-04-3-4 AASHTO T304-11 (Verified)
DIME Test ID: 2019-01-04-3-5 AASHTO T335-09r13 (Verified)
DIME Test ID: 2019-01-04-3-6 AASHTO T85-13 (Verified)
DIME Test ID: 2019-01-04-3-7 AASHTO T96-02r10 (Verified)
DIME Test ID: 2019-01-04-3-8 AASHTO T210-15 (Verified)
DIME Test ID: 2019-01-04-3-9 AASHTO T210-15 (Verified)
DIME Test ID: 2019-01-04-3-10 ASTM D4791-10 (Verified)
DIME Test ID: 2019-01-04-3-11 AASHTO T176-08 (Verified)
DIME Test ID: 2019-01-04-3-12 AASHTO T27-14 (Verified)
DIME Test ID: 2019-01-04-3-13 AASHTO T27-14 (Verified)
DIME Test ID: 2019-01-04-3-14 AASHTO T27-14 (Verified)
DIME Test ID: 2019-01-04-3-15 CTM 227-December 2014 (Verified)
DIME Test ID: 2019-01-04-3-16 AASHTO T27-14 (Verified)
DIME Test ID: 2019-01-04-3-17 AASHTO T27-14 (Verified)
DIME Test ID: 2019-01-04-3-18 AASHTO T27-14 (Verified)
DIME Test ID: 2019-01-04-3-19 AASHTO T27-14 (Verified)
DIME Test ID: 2019-01-04-3-20 AASHTO T27-14 (Verified)
DIME Test ID: 2019-01-04-3-21 AASHTO T27-14 (Verified)
DIME Test ID: 2019-01-04-3-22 AASHTO T84-14 (Verified)