Sample Record

DIME Sample ID 2018-09-06-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 212687
DEA: 06442544
EFIS: 0612000175
DIST-CO-RTE-PM06-KER-46,5-31.5-33.2
Award Date01/11/2018
Closeout Date11/19/2021
Work DescriptionCONVERT 2-LANE TO 4-LANE CONVENTIONAL HIGHWAY.
Location DescriptionKERN COUNTY NEAR LOST HILLS FROM 1.0 MILE EAST OF LOST HILLS ROAD TO 0.7 MILE EAST OF ROUTE 46/5 SEPARATION
QA Service Level1 (Verified on 03/12/2018)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date09/06/2018 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing09/10/2018 Sample typeQuality Assurance
A brief description of the sampleResistance Butt Welded Hoops The quantity of what the sample constitutes2100
From where was the sample collectedFabricator First name of sampler or witnessed bySherri
Last name of sampler or witnessed byBrannon Title of samplerQA Inspector
Telephone number of sampler7077918219 Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameTNT Rebar Company
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormL48-102-18
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)461717
Hoop Manufacturer Lot Number(s)23 27 30 36 Material Standard CodeASTM A706
Material Grade60 Rebar Size5
Diameter of Hoop1'-4" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCascade
Welding CompanyTNT Rebar Company Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2018-09-06-1-11CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory09/11/201809/11/2018
Yes
09/18/2018Bar Broke; OK NeckingPublic - Test Data Visible
2018-09-06-1-12CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory09/11/201809/11/2018
Yes
09/18/2018Bar Broke; OK NeckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-09-06-1-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-09-06-1-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-09-06-1-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-09-06-1-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-09-06-1-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-09-06-1-6 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-09-06-1-7 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-09-06-1-8 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-09-06-1-9 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-09-06-1-10 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-09-06-1-11 CTM 670-December 2013 (Verified)