Sample Record
Owner Lab
- CT D02 - Redding Northern Regional Laboratory
DIME Sample ID 2018-05-16-13
Project Information
| Project Identifiers | Project ID: 211705 DEA: 024G3804 EFIS: 0214000006 |
|---|---|
| DIST-CO-RTE-PM | 02-TRI-299-0.0/8.3 |
| Award Date | 11/30/2016 |
| Closeout Date | 01/02/2019 |
| Work Description | PLACE RUBBERIZED HOT MIX ASPHALT, GUARDRAIL, AND SOME DRAINAGE |
| Location Description | TRINITY COUNTY AT AND NEAR SALYER FROM HUMBOLDT COUNTY LINE TO 0.6 MILE EAST OF GRAY CREEK ROAD |
| QA Service Level | 1 (Verified on 10/25/2017) |
Sample Information
| Sample Taken Date | 05/16/2018 | Sample Unique Key | 13 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/16/2018 |
| Sample type | Department Acceptance | A brief description of the sample | JMF 1/2 OGFC-O Virgin agg bins |
| The quantity of what the sample constitutes | JMF 6 bags | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Dave | Last name of sampler or witnessed by | Lockett |
| Title of sampler | Tech | Telephone number of sampler | Unknown |
| Laboratory sample identification | JMF D77398 | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Mercer Fraser Willow Crk | Transportation Laboratory (TL) Number | T101 C 002137 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | T101 C002137 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | unknown |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | Virgin Aggregate 3 bins | The fabricator/manufacturer designation for the sample | Unknown |
| The plant number | Unknown | A detailed description of where the material sample was collected | Plant |
| Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 1/2 inch |
| The concrete mix design number | Unknown | Lot number | Not set |
| Sublot number | Not set | Aggregate Mix Number | Not set |
| HMA Pay | No |
Submitted Tests
| DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Date Added | Verified? | Release Date | Test Comments | Privacy Level | Actions |
|---|---|---|---|---|---|---|---|---|---|
| 2018-05-16-13-11 | AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles) | Terry McCormick, CT D02 - Redding Northern Regional Laboratory | 06/04/2018 | No | JMF 1/2 OGFC-O virgin aggregate quality testing | ||||
| 2018-05-16-13-12 | ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles) | Terry McCormick, CT D02 - Redding Northern Regional Laboratory | 06/05/2018 | No | JMF 1/2 OGFC-O virgin aggregate quality testing |
Go to page:
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2018-05-16-13-1 AASHTO T27-14
DIME Test ID: 2018-05-16-13-2 AASHTO T27-14
DIME Test ID: 2018-05-16-13-3 AASHTO T27-14
DIME Test ID: 2018-05-16-13-4 AASHTO T27-14
DIME Test ID: 2018-05-16-13-5 AASHTO T84-14
DIME Test ID: 2018-05-16-13-6 AASHTO T85-13
DIME Test ID: 2018-05-16-13-7 AASHTO T304-11
DIME Test ID: 2018-05-16-13-8 CTM 204-June 2010
DIME Test ID: 2018-05-16-13-9 AASHTO T210-15
DIME Test ID: 2018-05-16-13-10 AASHTO T96-02r10
DIME Test ID: 2018-05-16-13-11 AASHTO T335-09r13
DIME Test ID: 2018-05-16-13-12 ASTM D4791-10