Sample Record

DIME Sample ID 2026-06-04-37

Project Information

Project IdentifiersProject ID: 1001360
DEA: 09374804
EFIS: 0918000020
DIST-CO-RTE-PM09-INY-395-115.0
Award DateNot set
Closeout DateNot set
Work DescriptionBUILDING WORK AND PLACE HMA (TYPE A).
Location DescriptionINYO COUNTY IN BISHOP AT THE DISTRICT OFFICE AT 500 SOUTH MAIN STREET
QA Service Level1 (Verified on 07/09/2025)

Owner Labs

  • CT HQ - QASI Los Angeles Field Office
  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date06/04/2026 Sample Unique Key37
Date that the sample was received by the laboratory/organization performing the testing06/15/2026 Sample typeQuality Assurance
A brief description of the sampleASTM F1554 Grade 36 Anchor Bolts The quantity of what the sample constitutes110
From where was the sample collectedDistributor First name of sampler or witnessed byArthur
Last name of sampler or witnessed byPeterson Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility namePortland Bolt Manufacturing
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)N/A
Heat Number(s)2120451, 1000131533, 240151 Nut Mfg. Lot Number(s)W000320323
Washer Mfg. Lot Number(s)1024-447 Bolt SpecificationASTM F1554 GR 36
Bolt Length(s)10" Nut SpecificationASTM A563 Grade DH
Washer SpecificationASTM F436 FinishHDG
Diameter/Size5/8" Bolt Mfg. Lot NumberN/A
Rocap Test Requirement(s)NA Lubricant Requirements(s)NA
Washer Inner Diameter(s)NA Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2026-06-04-37-11ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)Andrew Auvinen, CT HQ - Sacramento Structural Materials Testing Laboratory06/25/202606/25/2026
Yes
06/30/2026BoltPublic - Test Data Visible
2026-06-04-37-13ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory06/30/202606/30/2026
Yes
06/30/2026Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2026-06-04-37-1 ASME B1.2-83r17 (Verified)
DIME Test ID: 2026-06-04-37-2 ASME B1.2-83r17 (Verified)
DIME Test ID: 2026-06-04-37-3 ASTM B499-09r21 (Verified)
DIME Test ID: 2026-06-04-37-4 ASTM B499-09r21 (Verified)
DIME Test ID: 2026-06-04-37-5 ASTM B499-09r21 (Verified)
DIME Test ID: 2026-06-04-37-6 ASTM B499-09r21 (Verified)
DIME Test ID: 2026-06-04-37-7 ASTM B499-09r21 (Verified)
DIME Test ID: 2026-06-04-37-8 ASTM B499-09r21 (Verified)
DIME Test ID: 2026-06-04-37-9 ASTM E18-20 (Verified)
DIME Test ID: 2026-06-04-37-10 ASTM E18-20 (Verified)
DIME Test ID: 2026-06-04-37-11 ASTM F606-21 (Verified)