Sample Record

DIME Sample ID 2026-02-23-2

Project Information

Project IdentifiersProject ID: 995236
DEA: 060U2904
EFIS: 0616000001
DIST-CO-RTE-PM06-KER-184-1.1/8.3
Award Date08/14/2025
Closeout DateNot set
Work DescriptionCOLD PLANE & OVERLAY WITH HMA/RHMA, CONSTRUCT SIDEWALKS & CURB RAMPS.
Location DescriptionKERN COUNTY NEAR BAKERSFIELD FROM WHARTON AVENUE TO EDISON HIGHWAY
QA Service Level1 (Verified on 12/18/2024)

Owner Labs

  • CT HQ - QASI Los Angeles Field Office
  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date02/23/2026 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing03/02/2026 Sample typePer Request
A brief description of the sample1-1/2" Anchor Bolt Assembly The quantity of what the sample constitutes40
From where was the sample collectedFabricator First name of sampler or witnessed byAlexis
Last name of sampler or witnessed byMillan Title of samplerCT QA METS Inspector
Telephone number of sampler9097569960 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameHalo Structural Products
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL191-025-26
Structure unique identifier Structure name
Bid Item122 - LIGHTING SYSTEM

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)NA
Heat Number(s)58067976, 256364, 149367 Nut Mfg. Lot Number(s)43251-256364
Washer Mfg. Lot Number(s)E7281 Bolt SpecificationASTM F1554 Gr 55 S-1
Bolt Length(s)41" Nut SpecificationASTM A563
Washer SpecificationASTM F436 FinishHDG
Diameter/Size1-1/2" Bolt Mfg. Lot Number58067976/03
Rocap Test Requirement(s)NA Lubricant Requirements(s)NA
Washer Inner Diameter(s)NA Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2026-02-23-2-11ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)Andrew Auvinen, CT HQ - Sacramento Structural Materials Testing Laboratory03/09/202603/09/2026
Yes
03/17/2026Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2026-02-23-2-1 ASME B1.2-83r17 (Verified)
DIME Test ID: 2026-02-23-2-2 ASTM B499-09r21 (Verified)
DIME Test ID: 2026-02-23-2-3 ASTM B499-09r21 (Verified)
DIME Test ID: 2026-02-23-2-4 ASTM B499-09r21 (Verified)
DIME Test ID: 2026-02-23-2-5 ASTM B499-09r21 (Verified)
DIME Test ID: 2026-02-23-2-6 ASTM B499-09r21 (Verified)
DIME Test ID: 2026-02-23-2-7 ASTM E18-20 (Verified)
DIME Test ID: 2026-02-23-2-8 ASTM E18-20 (Verified)
DIME Test ID: 2026-02-23-2-9 ASTM E18-20 (Verified)
DIME Test ID: 2026-02-23-2-10 ASTM E18-20 (Verified)
DIME Test ID: 2026-02-23-2-11 ASTM F606-21 (Verified)