Sample Record

Owner Lab

  • CT HQ - FFS - Skid Testing

DIME Sample ID 2025-04-01-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 994673
DEA: 033F0704
EFIS: 0312000054
DIST-CO-RTE-PM03-SAC-51-2.0/3.5
Award Date08/17/2023
Closeout DateNot set
Work DescriptionAmerican River Bridge Rehabilitation
Location DescriptionNot set
QA Service Level1 (Verified on 05/15/2023)

Sample Information

Sample Taken Date04/01/2025 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/01/2025
Sample typeAcceptance A brief description of the samplePCC
The quantity of what the sample constitutesBRIDGE DECK From where was the sample collectedJob Site
First name of sampler or witnessed byHARISH Last name of sampler or witnessed byTHAKUR
Title of sampler Telephone number of sampler9152961873
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAMERICAN RIVER BRIDGE Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeRoadway/Bridge Surface Pavement Surface TypePCC (Portland Cement Concrete)
Type of Traffic Control ProvidedBehind K-Rail/Barrier DIST-CO-RTE
Direction of Travel Post Mile
Lanes to be Tested Station

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2025-04-01-1-4CTM 342-August 2012: Method of Test for Surface Skid Resistance with the California Portable Skid Tester (Skid)HARISH THAKUR, CT HQ - FFS - Skid Testing04/02/202504/02/2025
Yes
04/02/2025AMERICAN RIVER BR/-#24-0003 LANE #1 @ 1300FTPublic - Test Data Visible
2025-04-01-1-5CTM 342-August 2012: Method of Test for Surface Skid Resistance with the California Portable Skid Tester (Skid)HARISH THAKUR, CT HQ - FFS - Skid Testing04/02/202504/02/2025
Yes
04/02/2025AMERICAN RIVER BR/-#24-0003 LANE #1 @ 1800FTPublic - Test Data Visible
2025-04-01-1-13CTM 342-August 2012: Method of Test for Surface Skid Resistance with the California Portable Skid Tester (Skid)HARISH THAKUR, CT HQ - FFS - Skid Testing04/08/202504/08/2025
Yes
04/08/2025AMERICAN RIVER BR/-#24-0003 LANE #1 @ 300Public - Test Data Visible
2025-04-01-1-14CTM 342-August 2012: Method of Test for Surface Skid Resistance with the California Portable Skid Tester (Skid)HARISH THAKUR, CT HQ - FFS - Skid Testing04/08/202504/08/2025
Yes
04/08/2025AMERICAN RIVER BR/-#24-0003 LANE #1 @ 800FTPublic - Test Data Visible
2025-04-01-1-15CTM 342-August 2012: Method of Test for Surface Skid Resistance with the California Portable Skid Tester (Skid)HARISH THAKUR, CT HQ - FFS - Skid Testing04/08/202504/08/2025
Yes
04/08/2025AMERICAN RIVER BR/-#24-0003 LANE #1 @ 1300FTPublic - Test Data Visible
2025-04-01-1-16CTM 342-August 2012: Method of Test for Surface Skid Resistance with the California Portable Skid Tester (Skid)HARISH THAKUR, CT HQ - FFS - Skid Testing04/08/202504/08/2025
Yes
04/08/2025AMERICAN RIVER BR/-#24-0003 LANE #1 @ 1800 FTPublic - Test Data Visible
2025-04-01-1-17CTM 342-August 2012: Method of Test for Surface Skid Resistance with the California Portable Skid Tester (Skid)HARISH THAKUR, CT HQ - FFS - Skid Testing04/08/202504/08/2025
Yes
04/08/2025AMERICAN RIVER BR/-#24-0003 DEPARTURE SLAB LANE #1Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2025-04-01-1-1 CTM 342-August 2012 (Verified)
DIME Test ID: 2025-04-01-1-2 CTM 342-August 2012 (Verified)
DIME Test ID: 2025-04-01-1-8 CTM 342-August 2012 (Verified)
DIME Test ID: 2025-04-01-1-10 CTM 342-August 2012 (Verified)
DIME Test ID: 2025-04-01-1-9 CTM 342-August 2012 (Verified)
DIME Test ID: 2025-04-01-1-12 CTM 342-August 2012 (Verified)
DIME Test ID: 2025-04-01-1-11 CTM 342-August 2012 (Verified)
DIME Test ID: 2025-04-01-1-7 CTM 342-August 2012 (Verified)
DIME Test ID: 2025-04-01-1-6 CTM 342-August 2012 (Verified)
DIME Test ID: 2025-04-01-1-3 CTM 342-August 2012 (Verified)
DIME Test ID: 2025-04-01-1-4 CTM 342-August 2012 (Verified)
DIME Test ID: 2025-04-01-1-5 CTM 342-August 2012 (Verified)
DIME Test ID: 2025-04-01-1-13 CTM 342-August 2012 (Verified)
DIME Test ID: 2025-04-01-1-14 CTM 342-August 2012 (Verified)
DIME Test ID: 2025-04-01-1-15 CTM 342-August 2012 (Verified)
DIME Test ID: 2025-04-01-1-16 CTM 342-August 2012 (Verified)
DIME Test ID: 2025-04-01-1-17 CTM 342-August 2012 (Verified)