Sample Record
Owner Lab
- CT HQ - QASI Bay Area Field Office
DIME Sample ID 2024-10-17-3
Project Information
| Project Identifiers | Project ID: 993818 DEA: 07322504 EFIS: 0716000056 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-103-0.1/0.1 |
| Award Date | 03/22/2024 |
| Closeout Date | 10/23/2025 |
| Work Description | UNION PACIFIC OH DECK REHABILITATION |
| Location Description | THE CITY AND COUNTY OF LOS ANGELES AT UNION PACIFIC OVERHEAD |
| QA Service Level | 1 (Verified on 05/11/2022) |
Sample Information
| Sample Taken Date | 10/17/2024 | Sample Unique Key | 3 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 10/21/2024 |
| Sample type | Quality Assurance | A brief description of the sample | 7/8-9x3 F3125 A325 Heavy Hex Bolt Assembly |
| The quantity of what the sample constitutes | 432 pcs | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Sherri | Last name of sampler or witnessed by | Brannon |
| Title of sampler | CT METS QA INSPECTOR | Telephone number of sampler | 9168266371 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | C&K Johnson | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B22-050-24 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 4163634 |
|---|---|---|---|
| Heat Number(s) | B 10890180 N 20858460 W 233165 | Nut Mfg. Lot Number(s) | E20601 |
| Washer Mfg. Lot Number(s) | E5703 | Bolt Specification | A325 |
| Bolt Length(s) | 3 | Nut Specification | A563 |
| Washer Specification | F436 | Finish | Hot Dip Galva |
| Diameter/Size | 7/8-9x3 | Bolt Mfg. Lot Number | E584Q1 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Submitted Tests
Go to page:
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2024-10-17-3-1 ASTM B499-09r21 (Verified)
DIME Test ID: 2024-10-17-3-2 ASTM B499-09r21 (Verified)
DIME Test ID: 2024-10-17-3-3 ASTM B499-09r21 (Verified)
DIME Test ID: 2024-10-17-3-4 ASTM B499-09r21 (Verified)
DIME Test ID: 2024-10-17-3-5 ASTM B499-09r21 (Verified)
DIME Test ID: 2024-10-17-3-6 ASTM B499-09r21 (Verified)
DIME Test ID: 2024-10-17-3-7 ASTM B499-09r21 (Verified)
DIME Test ID: 2024-10-17-3-8 ASTM B499-09r21 (Verified)
DIME Test ID: 2024-10-17-3-9 ASTM B499-09r21 (Verified)
DIME Test ID: 2024-10-17-3-10 ASTM E18-20 (Verified)
DIME Test ID: 2024-10-17-3-11 ASTM E18-20 (Verified)
DIME Test ID: 2024-10-17-3-12 ASTM E18-20 (Verified)
DIME Test ID: 2024-10-17-3-13 ASTM E18-20 (Verified)
DIME Test ID: 2024-10-17-3-14 ASTM E18-20 (Verified)
DIME Test ID: 2024-10-17-3-15 ASTM E18-20 (Verified)
DIME Test ID: 2024-10-17-3-16 ASTM E18-20 (Verified)
DIME Test ID: 2024-10-17-3-17 ASTM E18-20 (Verified)
DIME Test ID: 2024-10-17-3-18 ASTM E18-20 (Verified)