Combined Gradation Report

Report Name: HMA Aggregates (Size 3/4"): Type A HMA - Continuous Mixing Plant - Sieve Analysis With RAP
Report ID: Combined Gradation-2024-06-65
Specification: 2023 Caltrans Standard Specification - Type A HMA 3/4 inch

Subsample

Material

DIME Sample ID

Test Method

Percentage

Other

1

Aggregate

2024-06-25-43

AASHTO T27-14

Percentage 75 %

2

Aggregate

2024-06-25-42

AASHTO T30-19

Percentage 25 %

Total WT 2110.6 g

Correction Factor: Yes

Combined Gradation

100 %

Target Value

Specification Limits

(Target Value ± Tolerance)

Sieve Size

% PASS% USEDWT RETCF% PASS% USED
% PASS

% PASS

% PASS

2"

10075.00.0010025.0

100

100 -

1½"

10075.00.0010025.0

100

100 -

1"

10075.00.0010025.0

100

100 100 - 100

¾"

9470.418.30.29924.8

95

91 86 - 96

½"

7757.7267.1-5.18220.6

78

77 71 - 83

⅜"

6548.4374.7-5.17719.3

68

70 -

No. 4

3425.7729.1-6.55914.7

40

44 39 - 49

No. 8

2317.31,001.6-35012.4

30

29 24 - 34

No. 16

1713.11,256.1-2.4389.5

23

21 -

No. 30

139.61,461.1-2.4287.1

17

15 11 - 19

No. 50

96.51,643.9-2.7194.9

11

10 -

No. 100

54.11,802.4-2.5123.0

7

6 -

No. 200

3.52.61,919.0-2.17.01.7

4.3

3.3 1.3 - 5.3

General comments

CF-R147 Coldfeed

CF-R146 RAP

Gradation By: Derek Carrington
Report Comment: CF-R147
Published By: Derek Carrington
Published Date: 2024-06-27
Published Comment: CF-R147